Author: Emperador, Francis; Bennett, Sean R; Gonzalez, Julia; Saati, Ahmed; Alsaywid, Basim S; Fernandez, Jose A
Title: Extravascular Lung Water and Effect on Oxygenation Assessed by Lung Ultrasound in Adult Cardiac Surgery Cord-id: dzah4ftj Document date: 2020_8_23
ID: dzah4ftj
Snippet: Introduction The extravascular lung water content is determined by the use of lung ultrasound (LUS) which is represented as B-lines. The aim of this study was to investigate whether the LUS measurement of extravascular lung water was correlated to changes in oxygenation. Methods This prospective cohort study was comprised of 73 patients with an average age of 56 (range: 18 to 87 years) who underwent elective cardiac surgery using cardiopulmonary bypass. The LUS score was performed preoperatively
Document: Introduction The extravascular lung water content is determined by the use of lung ultrasound (LUS) which is represented as B-lines. The aim of this study was to investigate whether the LUS measurement of extravascular lung water was correlated to changes in oxygenation. Methods This prospective cohort study was comprised of 73 patients with an average age of 56 (range: 18 to 87 years) who underwent elective cardiac surgery using cardiopulmonary bypass. The LUS score was performed preoperatively, time zero (T0), at one hour (T1), and at 24 hours (T2) post-surgery. Additionally, arterial oxygen partial pressure and fraction of inspired oxygen (PaO(2)/FiO(2)) ratio were measured at each time and the time-to-extubation. Results A negative correlation was found between the LUS score and PaO(2)/FiO(2) at T1 (p < 0.004). Extubation time and changes in the lung ultrasound score at T0 - T2 were positively correlated (p < 0.03). Plus, there was a positive correlation between fluid balance and lung ultrasound score at T2 (p < 0.03). Conclusion We found three significant correlations that support the use of LUS in cardiac surgery: 1) the more B-lines, the lower the oxygenation; 2) the more B-lines, the longer the period of ventilation; 3) the more B-lines, the more positive the fluid balance. LUS is a non-invasive bedside investigation that can be used to judge extravascular lung water, providing useful information in the management of patient oxygenation, fluid balance, and extubation.
Search related documents:
Co phrase search for related documents- lung disease and lus accuracy: 1, 2, 3, 4
- lung disease and lus assess: 1, 2
- lung disease and lus compare: 1, 2
- lung disease and lus examination: 1, 2, 3, 4, 5, 6
- lung disease and lus experience: 1, 2
- lung disease and lus impact: 1
- lung disease and lus investigate: 1, 2
- lung disease and lus lung ultrasound: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36
- lung disease and lus method: 1, 2, 3, 4
- lung disease and lus score increase: 1
- lung ultrasound and lus accuracy: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24
- lung ultrasound and lus appear: 1, 2
- lung ultrasound and lus assess: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30
- lung ultrasound and lus change: 1
- lung ultrasound and lus compare: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- lung ultrasound and lus examination: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24
- lung ultrasound and lus experience: 1, 2, 3, 4, 5
- lung ultrasound and lus impact: 1, 2, 3
- lung ultrasound and lus investigate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
Co phrase search for related documents, hyperlinks ordered by date