Selected article for: "nasopharyngeal nasal and real time"

Author: Kiyasu, Y.; Owaku, M.; Akashi, Y.; Takeuchi, Y.; Narahara, K.; Mori, S.; Nagano, T.; Notake, S.; Ueda, A.; Nakamura, K.; Ishikawa, H.; Suzuki, H.
Title: Clinical Evaluation of the Novel Rapid Nucleic Acid Amplification Point-of-Care Test (Smart Gene SARS-CoV-2) in the analysis of Nasopharyngeal and Anterior Nasal samples.
  • Cord-id: axxb49xm
  • Document date: 2021_8_28
  • ID: axxb49xm
    Snippet: Introduction Smart Gene is a point-of-care (POC)-type automated molecular testing platform that can be performed with 1 minute of hands-on-time. Smart Gene SARS-CoV-2 is a newly developed Smart Gene molecular assay for the detection of SARS-CoV-2. The analytical and clinical performance of Smart Gene SARS-CoV-2 has not been evaluated. Methods Nasopharyngeal and anterior nasal samples were prospectively collected from subjects referred to the local PCR center from March 25 to July 5, 2021. Two sw
    Document: Introduction Smart Gene is a point-of-care (POC)-type automated molecular testing platform that can be performed with 1 minute of hands-on-time. Smart Gene SARS-CoV-2 is a newly developed Smart Gene molecular assay for the detection of SARS-CoV-2. The analytical and clinical performance of Smart Gene SARS-CoV-2 has not been evaluated. Methods Nasopharyngeal and anterior nasal samples were prospectively collected from subjects referred to the local PCR center from March 25 to July 5, 2021. Two swabs were simultaneously obtained for the Smart Gene SARS-CoV-2 assay and the reference real-time RT-PCR assay, and the results of Smart Gene SARS-CoV-2 were compared to the reference real-time RT-PCR assay. Results Among a total of 1150 samples, 68 of 791 nasopharyngeal samples and 51 of 359 anterior nasal samples were positive for SARS-CoV-2 in the reference real-time RT-PCR assay. In the testing of nasopharyngeal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 99.2% (95% confidence interval [CI]: 98.4-99.7%), 94.1% (95% CI: 85.6-98.4%) and 99.7% (95% CI: 99.0-100%), respectively. For anterior nasal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 98.9% (95% CI: 97.2-99.7%), 98.0% (95% CI: 89.6-100%) and 99.0% (95% CI: 97.2-99.8%), respectively. In total, 5 samples were positive in the reference real-time RT-PCR and negative in Smart Gene SARS-CoV-2, whereas 5 samples were negative in the reference real-time RT-PCR and positive in Smart Gene SARS-CoV-2. Conclusion Smart Gene SARS-CoV-2 showed sufficient analytical performance for the detection of SARS-CoV-2 in nasopharyngeal and anterior nasal samples.

    Search related documents:
    Co phrase search for related documents
    • accuplex sars and lod detection limit: 1, 2
    • accuplex sars and lod evaluation: 1
    • accurate quick and lod detection: 1, 2, 3
    • accurate quick and lod detection limit: 1, 2, 3
    • accurate quick and long term care facility: 1
    • acid amplification test and lod detection: 1
    • acid amplification test and lod detection limit: 1
    • acid amplification test and long term care facility: 1