Author: Zheng, Yu-Zhong; Chen, Jiang-Tao; Li, Jian; Wu, Xian-Jing; Wen, Jin-Zhou; Liu, Xiang-Zhi; Lin, Li-Yun; Liang, Xue-Yan; Huang, Hui-Ying; Zha, Guang-Cai; Yang, Pei-Kui; Li, Lie-Jun; Zhong, Tian-Yu; Liu, Long; Cheng, Wei-Jia; Song, Xiao-Nan; Lin, Min
Title: Reverse Transcription Recombinase-Aided Amplification Assay With Lateral Flow Dipstick Assay for Rapid Detection of 2019 Novel Coronavirus Cord-id: 5hwge5cl Document date: 2021_2_1
ID: 5hwge5cl
Snippet: BACKGROUND: The emerging Coronavirus Disease-2019 (COVID-19) has challenged the public health globally. With the increasing requirement of detection for SARS-CoV-2 outside of the laboratory setting, a rapid and precise Point of Care Test (POCT) is urgently needed. METHODS: Targeting the nucleocapsid (N) gene of SARS-CoV-2, specific primers, and probes for reverse transcription recombinase-aided amplification coupled with lateral flow dipstick (RT-RAA/LFD) platform were designed. For specificity
Document: BACKGROUND: The emerging Coronavirus Disease-2019 (COVID-19) has challenged the public health globally. With the increasing requirement of detection for SARS-CoV-2 outside of the laboratory setting, a rapid and precise Point of Care Test (POCT) is urgently needed. METHODS: Targeting the nucleocapsid (N) gene of SARS-CoV-2, specific primers, and probes for reverse transcription recombinase-aided amplification coupled with lateral flow dipstick (RT-RAA/LFD) platform were designed. For specificity evaluation, it was tested with human coronaviruses, human influenza A virus, influenza B viruses, respiratory syncytial virus, and hepatitis B virus, respectively. For sensitivity assay, it was estimated by templates of recombinant plasmid and pseudovirus of SARS-CoV-2 RNA. For clinical assessment, 100 clinical samples (13 positive and 87 negatives for SARS-CoV-2) were tested via quantitative reverse transcription PCR (RT-qPCR) and RT-RAA/LFD, respectively. RESULTS: The limit of detection was 1 copies/μl in RT-RAA/LFD assay, which could be conducted within 30 min at 39°C, without any cross-reaction with other human coronaviruses and clinical respiratory pathogens. Compared with RT-qPCR, the established POCT assay offered 100% specificity and 100% sensitivity in the detection of clinical samples. CONCLUSION: This work provides a convenient POCT tool for rapid screening, diagnosis, and monitoring of suspected patients in SARS-CoV-2 endemic areas.
Search related documents:
Co phrase search for related documents- acid amplification and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- acid amplification and low concentration: 1, 2, 3, 4
- acid amplification and low resource: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- lod detection limit and low concentration: 1, 2, 3, 4, 5, 6
- lod detection limit and low resource: 1, 2, 3
Co phrase search for related documents, hyperlinks ordered by date