Title: A novel loop-mediated isothermal amplification method for efficient and robust detection of EGFR mutations Document date: 2020_1_14
ID: 4sltubqk_15
Snippet: The sensitivity, specificity, PPV, NPV and accuracy values of LAMP for EGFR mutations compared with the Therascreen assay method were 97, 100, 100, 96.3 and 98.3%, respectively, demonstrating the potential of LAMP as an efficient alternative approach t oncogene mutation analyses. To evaluate the sensitivity of these two assays, a genetic analysis was performed to investigate the minimum concentration of EGFR mutation detection in both methods. Th.....
Document: The sensitivity, specificity, PPV, NPV and accuracy values of LAMP for EGFR mutations compared with the Therascreen assay method were 97, 100, 100, 96.3 and 98.3%, respectively, demonstrating the potential of LAMP as an efficient alternative approach t oncogene mutation analyses. To evaluate the sensitivity of these two assays, a genetic analysis was performed to investigate the minimum concentration of EGFR mutation detection in both methods. The minimum concentration for LAMP was 4.8% and there were no detection under 1.0% in the Therascreen assay. Therefore, the minimum concentration for the LAMP assay is ~50 times higher than 4.8% in the Therascreen assay. With almost equal efficiency, detection of the exon 19 mutation in Case X using the Therascreen method suggested that LAMP, as well as direct sequence methods, could identify false negatives. However, additional experiments investigating Case X tumor tissues demonstrated the presence of deletion mutations in exon 19. The direct sequence method has reported low sensitivity (31, 32) , whereas the Therascreen method was generally recognized as a promising method (11, 12) . However, the identified mutation should be simplified, and an improved, faster and cheaper method of identification should be developed for its clinical application.
Search related documents:
Co phrase search for related documents- accuracy NPV PPV specificity sensitivity and assay sensitivity: 1
- alternative approach and assay method: 1, 2
- alternative approach and assay sensitivity: 1, 2, 3, 4
- alternative approach and clinical application: 1, 2, 3
- alternative approach and direct sequence: 1
- assay method and clinical application: 1, 2, 3
- assay sensitivity and clinical application: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- deletion mutation and EGFR mutation: 1, 2, 3, 4, 5
Co phrase search for related documents, hyperlinks ordered by date