Selected article for: "current dose and low dose"

Author: Yoon, Soon Ho; Lee, Kyung Hee; Kim, Jin Yong; Lee, Young Kyung; Ko, Hongseok; Kim, Ki Hwan; Park, Chang Min; Kim, Yun-Hyeon
Title: Chest Radiographic and CT Findings of the 2019 Novel Coronavirus Disease (COVID-19): Analysis of Nine Patients Treated in Korea
  • Document date: 2020_2_26
  • ID: 3hgy4msc_8
    Snippet: All CT examinations were performed using a multidetector CT scanner with 64 or more channels (Somatom Definition, Somatom Definition AS+, or Somatom Force, Siemens Healthineers, Erlangen, Germany). The detailed parameters for CT acquisition were as follows: tube voltage, 120 kVp; tube current, standard (reference mAs, 60-120) to low-dose (reference mAs, 30) with automatic exposure control; slice thickness, 1.0 mm; reconstruction interval, 1.0-3.0.....
    Document: All CT examinations were performed using a multidetector CT scanner with 64 or more channels (Somatom Definition, Somatom Definition AS+, or Somatom Force, Siemens Healthineers, Erlangen, Germany). The detailed parameters for CT acquisition were as follows: tube voltage, 120 kVp; tube current, standard (reference mAs, 60-120) to low-dose (reference mAs, 30) with automatic exposure control; slice thickness, 1.0 mm; reconstruction interval, 1.0-3.0 mm; and a sharp reconstruction kernel. CT images were obtained with the patient in the supine position at full inspiration and without contrast medium.

    Search related documents:
    Co phrase search for related documents
    • contrast medium and CT image: 1, 2
    • contrast medium and low dose: 1
    • contrast medium and mm slice thickness: 1
    • contrast medium and slice thickness: 1
    • CT acquisition and CT image: 1, 2, 3, 4, 5, 6, 7, 8
    • CT acquisition and low dose: 1, 2
    • CT examination and CT image: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
    • CT examination and CT scanner: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • CT examination and low dose: 1, 2, 3, 4, 5, 6, 7
    • CT examination and mm slice thickness: 1, 2
    • CT examination and multidetector CT scanner: 1
    • CT examination and slice thickness: 1, 2, 3, 4
    • CT image and CT scanner: 1, 2, 3, 4, 5, 6, 7
    • CT image and low dose: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
    • CT image and mm slice thickness: 1
    • CT image and slice thickness: 1, 2, 3, 4
    • CT image and supine position: 1
    • CT scanner and inspiration supine position patient: 1
    • CT scanner and low dose: 1, 2, 3, 4, 5, 6