Selected article for: "outdoor air and ventilation rate"

Author: Nazaroff, William W
Title: Indoor bioaerosol dynamics
  • Document date: 2014_12_27
  • ID: 6cargkwy_71
    Snippet: Regarding removal processes, the primary control alternatives are three, which appear in the denominator of equations (1) and (2): (i) increase the outdoor air ventilation rate (typically either Q N or Q M ); (ii) use recirculating air filtration (i.e., introduce or enhance g R Q R , where g R is the filtration efficiency, as illustrated in Figure 12 , and Q R is the recirculating flow rate through the filter; or (iii) enhance the rate of deposit.....
    Document: Regarding removal processes, the primary control alternatives are three, which appear in the denominator of equations (1) and (2): (i) increase the outdoor air ventilation rate (typically either Q N or Q M ); (ii) use recirculating air filtration (i.e., introduce or enhance g R Q R , where g R is the filtration efficiency, as illustrated in Figure 12 , and Q R is the recirculating flow rate through the filter; or (iii) enhance the rate of deposition or degradation of the bioaerosol attribute (thereby increasing b). Miller-Leiden et al. (1996) explored the effectiveness of in-room recirculating filtration for controlling the transmission of tuberculosis. Cheng et al. (1998) have evaluated the use of portable air cleaners for reducing indoor concentrations of fungal spores. Ultraviolet germicidal irradiation can be applied to reduce the infectivity of air without actively removing the bioaerosol particles (Reed, 2010) .

    Search related documents:
    Co phrase search for related documents
    • air cleaner and flow rate: 1, 2, 3
    • air cleaner and fungal spore: 1
    • air cleaner and germicidal irradiation: 1
    • air cleaner and portable air cleaner: 1, 2, 3
    • air filtration and bioaerosol particle: 1
    • air filtration and filtration efficiency: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • air filtration and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • air filtration and fungal spore: 1
    • air filtration and germicidal irradiation: 1, 2, 3, 4, 5
    • air filtration and indoor concentration: 1
    • air filtration and portable air cleaner: 1
    • air infectivity and filtration efficiency: 1, 2
    • air ventilation and filtration efficiency: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • air ventilation and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
    • air ventilation and fungal spore: 1
    • air ventilation and germicidal irradiation: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • air ventilation and indoor concentration: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • air ventilation and portable air cleaner: 1, 2, 3
    • air ventilation rate and portable air cleaner: 1