Selected article for: "outside reference laboratory and reference laboratory"

Author: Abdul-Khaliq, Catherine
Title: Development of a United Kingdom National External Quality Assessment Scheme (UK NEQAS) for HIV point of care testing
  • Document date: 2011_3_23
  • ID: 10omkpwl_24
    Snippet: Performance of POCT kits was investigated using a first set of specimens fully characterized by enzyme immunoassays (EIAs) and line assays. All specimens correctly showed reactive results for HIV-1 and HIV-2 antibody with all POCTs. However 7 of 20 specimens showed weak reactive results for HIV antibodies on both INSTI HIV 1/2 and OraQuick .................................................................................................................
    Document: Performance of POCT kits was investigated using a first set of specimens fully characterized by enzyme immunoassays (EIAs) and line assays. All specimens correctly showed reactive results for HIV-1 and HIV-2 antibody with all POCTs. However 7 of 20 specimens showed weak reactive results for HIV antibodies on both INSTI HIV 1/2 and OraQuick ...................................................................................................................................................................................................................................... Rapid HIV-1/2 antibody kits, including 3 of 16 HIV-1 and all four HIV-2 specimens. All specimens tested negative for HIV p24 antigen. All results were valid as control lines were clearly observed in all tests. Accuracy of the results obtained were assured as re-testing of the specimens using the Genscreen EIA matched those from the previous characterization and the results obtained from an outside reference laboratory.

    Search related documents:
    Co phrase search for related documents
    • antibody kit and enzyme immunoassay: 1, 2
    • antibody kit and HIV antibody: 1, 2
    • antibody kit and negative test: 1, 2, 3, 4, 5, 6, 7
    • control line and enzyme immunoassay: 1
    • control line and line assay: 1, 2, 3, 4
    • EIAs enzyme immunoassay and enzyme immunoassay: 1
    • enzyme immunoassay and HIV antibody: 1, 2
    • enzyme immunoassay and negative test: 1, 2, 3, 4
    • enzyme immunoassay and obtain result: 1
    • Genscreen EIA and line assay: 1
    • HIV antibody and negative test: 1, 2, 3
    • HIV antibody and OraQuick INSTI HIV HIV antibody: 1, 2, 3
    • line assay and negative test: 1
    • negative test and obtain result: 1, 2