Selected article for: "intervertebral disc and vertebral canal"

Title: Proceedings 31st Symposium ESVN-ECVN
  • Document date: 2019_12_21
  • ID: 4526ne4l_67
    Snippet: Nine dogs met the inclusion criteria for a total of 45 implants positioned. Immediately after surgery, all constructs were considered unlikely to impair neurovascular structures. Upon retrospective review, 35 screws were graded as optimal, 7 protruded outside the intended bone corridor but not within the vertebral canal (VC) and 3 actually caused VC violation. The cranial articular surface of the axis had the highest rate of optimal implant place.....
    Document: Nine dogs met the inclusion criteria for a total of 45 implants positioned. Immediately after surgery, all constructs were considered unlikely to impair neurovascular structures. Upon retrospective review, 35 screws were graded as optimal, 7 protruded outside the intended bone corridor but not within the vertebral canal (VC) and 3 actually caused VC violation. The cranial articular surface of the axis had the highest rate of optimal implant placement (17/18). Monocortical screws placed in the sagittal plane of the axis often penetrated C2‐3 intervertebral disc space (6/9). VC violation occurred most commonly when aiming for atlantal lateral masses (2/18).

    Search related documents:
    Co phrase search for related documents
    • bone corridor and intended bone corridor: 1
    • disc space and intervertebral disc space: 1, 2, 3, 4, 5
    • high rate and implant placement: 1, 2