Selected article for: "air exchange and flow rate"

Author: Nazaroff, William W
Title: Indoor bioaerosol dynamics
  • Document date: 2014_12_27
  • ID: 6cargkwy_39
    Snippet: The air exchange rate (AER) is an important metric for characterizing air quality aspects of buildings. This measure is the volume-normalized flow rate of air from the building to outdoors. As depicted in Figure 6 , the AER would be (Q N +Q L )/V for the residential sche- matic (i) and (Q M +Q L )/V for the commercial schematic (ii). Figure 8 presents a summary of AER data from two large studies conducted in the United States. The measurements in.....
    Document: The air exchange rate (AER) is an important metric for characterizing air quality aspects of buildings. This measure is the volume-normalized flow rate of air from the building to outdoors. As depicted in Figure 6 , the AER would be (Q N +Q L )/V for the residential sche- matic (i) and (Q M +Q L )/V for the commercial schematic (ii). Figure 8 presents a summary of AER data from two large studies conducted in the United States. The measurements in residences ( Figure 8a) show a median in the approximate range of 0.5-1 per hour. Considering individual households, most of the data lie within a range that spans about an order of magnitude, from 0.2 to 3 per hour. The BASE study of~100 commercial buildings (Figure 8b) shows a similar central tendency and a somewhat larger range, especially at the high end of the distribution. Each of these data sets conforms reasonably well to a lognormal distribution.

    Search related documents:
    Co phrase search for related documents
    • AER air exchange rate and air exchange rate: 1, 2, 3
    • AER air exchange rate and air quality: 1
    • air exchange and commercial building: 1
    • air exchange and flow rate: 1, 2, 3, 4
    • air exchange rate and flow rate: 1, 2, 3
    • air flow rate and commercial building: 1
    • air flow rate and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • air quality and central tendency: 1
    • air quality and commercial building: 1
    • air quality and data set: 1, 2, 3
    • air quality and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • BASE study and data set: 1
    • central tendency and data set: 1, 2
    • commercial building and flow rate: 1
    • data set and distribution high end: 1
    • data set and flow rate: 1, 2, 3
    • data set and high end: 1, 2
    • distribution high end and high end: 1
    • flow rate and high end: 1