Selected article for: "low high compliance and lung compliance"

Author: Hajjar, L. A.; Mauad, T.; Galas, F. R. B. G.; Kumar, A.; da Silva, L. F. F.; Dolhnikoff, M.; Trielli, T.; Almeida, J. P.; Borsato, M. R. L.; Abdalla, E.; Pierrot, L.; Kalil Filho, R.; Auler, J. O. C.; Saldiva, P. H. N.; Hoff, P. M.
Title: Severe novel influenza A (H1N1) infection in cancer patients
  • Document date: 2010_5_28
  • ID: 00rk8fb5_15
    Snippet: Patients who needed mechanical ventilation were managed with pressure-cycled ventilation, with a low tidal volume (target 6 ml/kg) open-lung strategy of ventilation, and a positive endexpiratory pressure (PEEP) titrated based on FiO 2 for goal plateau pressure (Pplat) < 30 cm H 2 O and SpO 2 88%-90% according to ARDS Network protocol. In some cases, due to refractory hypoxemia, PEEP levels of 14 to 16 cm H 2 O were applied. In all patients, recru.....
    Document: Patients who needed mechanical ventilation were managed with pressure-cycled ventilation, with a low tidal volume (target 6 ml/kg) open-lung strategy of ventilation, and a positive endexpiratory pressure (PEEP) titrated based on FiO 2 for goal plateau pressure (Pplat) < 30 cm H 2 O and SpO 2 88%-90% according to ARDS Network protocol. In some cases, due to refractory hypoxemia, PEEP levels of 14 to 16 cm H 2 O were applied. In all patients, recruitment maneuvers were usedcontinuous positive airway pressure 35-40 cm H 2 O for 30 swith short-term improvements in oxygenation in three of five patients (initial mean oxygen saturation rate increased from 88% to 94%). Neuromuscular blockade was used in two patients ( Table 2) . Despite the aforementioned ventilatory strategy, this particular group of patients developed refractory persistent hypoxemia. Lung mechanics of patients showed very low static and dynamic compliance and high airway resistance.

    Search related documents:
    Co phrase search for related documents
    • ARDS Network protocol and mechanical ventilation: 1, 2, 3
    • ARDS Network protocol and oxygen saturation rate: 1
    • endexpiratory pressure and mechanical ventilation: 1, 2
    • high airway and low tidal volume: 1, 2
    • high airway and mechanical ventilation: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • high airway and mechanical ventilation need: 1, 2, 3
    • high airway and neuromuscular blockade: 1
    • high airway and open lung: 1
    • high airway and open lung strategy: 1
    • high airway and oxygen saturation rate: 1, 2
    • high airway resistance and low tidal volume: 1
    • high airway resistance and mechanical ventilation: 1, 2
    • low tidal volume and mechanical ventilation: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • low tidal volume and mechanical ventilation need: 1
    • low tidal volume and neuromuscular blockade: 1, 2, 3, 4, 5, 6, 7
    • low tidal volume and open lung: 1, 2, 3
    • low tidal volume and open lung strategy: 1, 2
    • lung mechanic and mechanical ventilation: 1
    • mechanical ventilation and oxygen saturation rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25