Author: SUNAGA, Fujiko; TSUCHIAKA, Shinobu; KISHIMOTO, Mai; AOKI, Hiroshi; KAKINOKI, Mari; KURE, Katsumasa; OKUMURA, Hanako; OKUMURA, Maho; OKUMURA, Atsushi; NAGAI, Makoto; OMATSU, Tsutomu; MIZUTANI, Tetsuya
Title: Development of a one-run real-time PCR detection system for pathogens associated with porcine respiratory diseases Document date: 2019_12_23
ID: 0pkbbb99_10
Snippet: For the purpose of validation, real-time PCR reliability, sensitivity, and linearity of standard curves were verified by testing tenfold serial dilutions of synthesized DNA, including each target genome sequence (1 × 10 0 to 1 × 10 6 copies/reaction). The synthesized DNA was purchased from Integrated DNA Technologies (Integrated DNA Technologies, Inc.). Pathogen dilutions were repeated twice in separate runs, and a standard curve was constructe.....
Document: For the purpose of validation, real-time PCR reliability, sensitivity, and linearity of standard curves were verified by testing tenfold serial dilutions of synthesized DNA, including each target genome sequence (1 × 10 0 to 1 × 10 6 copies/reaction). The synthesized DNA was purchased from Integrated DNA Technologies (Integrated DNA Technologies, Inc.). Pathogen dilutions were repeated twice in separate runs, and a standard curve was constructed from the Cq values. The PCR efficiency (E) was calculated using the standard curve slope according to the following formula: E=(10 −1/slope (−1) ). The correlation co-efficient (R 2 ) was also calculated. The limit of detection (LOD) was defined as the lowest concentration at which a fluorescent signal could be detected in all reactions. Reproducibility (inter-assay variance) was assessed using the coefficient value (CV) calculated based on quantification cycle (Cq) values.
Search related documents:
Co phrase search for related documents- low concentration and quantification cycle: 1
- low concentration and reaction detect: 1, 2, 3
- low concentration and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
- low concentration and standard curve: 1
- low concentration and synthesized dna: 1
- PCR efficiency and quantification cycle: 1
- PCR efficiency and reaction detect: 1, 2, 3, 4, 5
- PCR efficiency and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28
- PCR efficiency and serial dilution: 1, 2
- PCR efficiency and standard curve: 1, 2, 3
- PCR efficiency and standard curve slope: 1
- PCR efficiency and synthesized dna: 1, 2
- pcr reliability and quantification cycle: 1
- pcr reliability and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9
- pcr reliability and real time pcr reliability: 1, 2, 3
- quantification cycle and reaction detect: 1
- quantification cycle and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- quantification cycle and separate run: 1
- quantification cycle and standard curve: 1
Co phrase search for related documents, hyperlinks ordered by date