Author: Kang, Jun Sik; Jhun, Byung Woo; Yoon, Hee; Lim, Seong Mi; Ko, Eunsil; Park, Joo Hyun; Hwang, Sung Yeon; Lee, Se Uk; Lee, Tae Rim; Cha, Won Chul; Shin, Tae Gun; Sim, Min Seob; Jo, Ik Joon
Title: The Utility of Preliminary Patient Evaluation in a Febrile Respiratory Infectious Disease Unit outside the Emergency Department Document date: 2017_7_3
ID: 0q2ky9gd_8
Snippet: The triage room is in the front of the FRIDU, which is located outside the ED ( Fig. 2A) , and includes an administration area, a nurses' triage area, and a doctor's examination room (Fig. 2B ). There are also 6 isolation rooms with negative pressure ventilation systems, each with a high-efficiency particulate air filter with an airtight backdraft damper (15-30 air changes per hour). An anteroom is located in front of every isolation room, and th.....
Document: The triage room is in the front of the FRIDU, which is located outside the ED ( Fig. 2A) , and includes an administration area, a nurses' triage area, and a doctor's examination room (Fig. 2B ). There are also 6 isolation rooms with negative pressure ventilation systems, each with a high-efficiency particulate air filter with an airtight backdraft damper (15-30 air changes per hour). An anteroom is located in front of every isolation room, and the inter-room pressure difference is −4.5 to −17 Pa. Portable radiological and ultrasound examinations, blood sample kits, polymerase chain reaction (PCR) tests for respiratory viruses, and sputum examination kits were available in every isolation and laboratory room. Oxygen supply systems (nasal prong, facial mask, etc.), devices for airway management and central vascu- lar access, mechanical ventilation, and remote vital sign monitors were also provided.
Search related documents:
Co phrase search for related documents- administration area and PCR polymerase chain reaction: 1
- administration area and polymerase chain reaction: 1, 2
- air change and high efficiency: 1, 2, 3, 4
- air change and hour air change: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- air change and isolation room: 1, 2, 3
- air change and mechanical ventilation: 1, 2, 3, 4, 5, 6, 7
- air change and pressure difference: 1, 2
- air change and respiratory virus: 1, 2
- air change and supply system: 1
- air filter and airway management: 1
- air filter and chain reaction: 1, 2, 3, 4, 5
- air filter and examination room: 1, 2
- air filter and high efficiency: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52
- air filter and hour air change: 1, 2
- air filter and isolation room: 1, 2, 3, 4, 5
- air filter and laboratory room: 1
- air filter and mechanical ventilation: 1, 2, 3, 4, 5, 6, 7
- air filter and negative pressure ventilation system: 1
- air filter and polymerase chain reaction: 1, 2, 3, 4, 5
Co phrase search for related documents, hyperlinks ordered by date