Selected article for: "negative pressure and pressure room"

Author: Kang, Jun Sik; Jhun, Byung Woo; Yoon, Hee; Lim, Seong Mi; Ko, Eunsil; Park, Joo Hyun; Hwang, Sung Yeon; Lee, Se Uk; Lee, Tae Rim; Cha, Won Chul; Shin, Tae Gun; Sim, Min Seob; Jo, Ik Joon
Title: The Utility of Preliminary Patient Evaluation in a Febrile Respiratory Infectious Disease Unit outside the Emergency Department
  • Document date: 2017_7_3
  • ID: 0q2ky9gd_8
    Snippet: The triage room is in the front of the FRIDU, which is located outside the ED ( Fig. 2A) , and includes an administration area, a nurses' triage area, and a doctor's examination room (Fig. 2B ). There are also 6 isolation rooms with negative pressure ventilation systems, each with a high-efficiency particulate air filter with an airtight backdraft damper (15-30 air changes per hour). An anteroom is located in front of every isolation room, and th.....
    Document: The triage room is in the front of the FRIDU, which is located outside the ED ( Fig. 2A) , and includes an administration area, a nurses' triage area, and a doctor's examination room (Fig. 2B ). There are also 6 isolation rooms with negative pressure ventilation systems, each with a high-efficiency particulate air filter with an airtight backdraft damper (15-30 air changes per hour). An anteroom is located in front of every isolation room, and the inter-room pressure difference is −4.5 to −17 Pa. Portable radiological and ultrasound examinations, blood sample kits, polymerase chain reaction (PCR) tests for respiratory viruses, and sputum examination kits were available in every isolation and laboratory room. Oxygen supply systems (nasal prong, facial mask, etc.), devices for airway management and central vascu- lar access, mechanical ventilation, and remote vital sign monitors were also provided.

    Search related documents:
    Co phrase search for related documents
    • air change and supply system: 1
    • air filter and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • airway management and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • airway management and triage area: 1
    • blood sample and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
    • chain reaction and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • chain reaction and respiratory virus test: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
    • chain reaction and supply system: 1, 2, 3, 4
    • examination room and respiratory virus: 1
    • facial mask and respiratory virus: 1, 2, 3, 4
    • high efficiency and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
    • high efficiency and supply system: 1, 2, 3
    • isolation room and respiratory virus: 1, 2, 3
    • isolation room and respiratory virus test: 1
    • isolation room and supply system: 1
    • laboratory room and respiratory virus: 1, 2, 3
    • mechanical ventilation and respiratory virus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • mechanical ventilation and supply system: 1, 2
    • oxygen supply system and supply system: 1, 2, 3, 4, 5