Author: Nazaroff, William W
Title: Indoor bioaerosol dynamics Document date: 2014_12_27
ID: 6cargkwy_49
Snippet: In the case of a mechanically ventilated building, a second important parameter is the efficiency of a particle filter in the flow path connecting outdoor air to the air supply registers. Figure 12 illustrates two important points about filter efficiency. First, it is highly variable with filter quality, ranging from low for filters with a MERV 4 rating to high for MERV 13 or MERV 16 filters. Second, filter efficiency can vary markedly with parti.....
Document: In the case of a mechanically ventilated building, a second important parameter is the efficiency of a particle filter in the flow path connecting outdoor air to the air supply registers. Figure 12 illustrates two important points about filter efficiency. First, it is highly variable with filter quality, ranging from low for filters with a MERV 4 rating to high for MERV 13 or MERV 16 filters. Second, filter efficiency can vary markedly with particle size. Across the range that is pertinent for bioaerosols, the filtration efficiency tends to be higher for larger particles than for smaller particles. A mechanically ventilated building with a high mechanical ventilation to infiltration flow rate ratio (Q M /Q L ≫ 1) and a high-efficiency filter (1Àg M ( 1) can provide a high degree of protection of the indoor environment from outdoor bioaerosols.
Search related documents:
Co phrase search for related documents- infiltration flow and mechanical ventilation: 1
- infiltration flow and outdoor air: 1
- infiltration flow and outdoor bioaerosol: 1
- infiltration flow and particle size: 1
- large particle and outdoor air: 1
- large particle and particle filter: 1, 2
- large particle and particle size: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- large particle and small particle: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- mechanical ventilation and outdoor air: 1, 2, 3, 4, 5
- mechanical ventilation and outdoor bioaerosol: 1, 2
- mechanical ventilation and particle size: 1, 2, 3, 4, 5, 6, 7
- mechanical ventilation and rate ratio: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65
- outdoor air and particle filter: 1
- outdoor air and particle size: 1, 2, 3
- outdoor air and rate ratio: 1, 2, 3
- outdoor bioaerosol and particle size: 1
- particle size and rate ratio: 1, 2, 3
- particle size and small particle: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23