Selected article for: "Bland Altman plotting and error grid analysis"

Title: 2017 ACVIM Forum Research Abstract Program
  • Document date: 2017_6_15
  • ID: ri2w5iby_276
    Snippet: Spearman correlation analysis revealed high correlations between the values obtained by the PBGMs and the reference method. However, Bland-Altman plotting showed that deviations of the PBGM values from the reference range increased when actual glucose concentrations increased. Decreased packed cell volume (PCV) resulted in overestimation or underestimation of blood glucose values from iPet and OneTouch Ultra, respectively. Hypertriglyceridemia re.....
    Document: Spearman correlation analysis revealed high correlations between the values obtained by the PBGMs and the reference method. However, Bland-Altman plotting showed that deviations of the PBGM values from the reference range increased when actual glucose concentrations increased. Decreased packed cell volume (PCV) resulted in overestimation or underestimation of blood glucose values from iPet and OneTouch Ultra, respectively. Hypertriglyceridemia resulted in overestimation of glucose values from AlphaTrak2, iPet, Cerapet, and VetMate. Hyperproteinemia resulted in overestimation of glucose values from One-Touch Ultra and Optium Xceed. Error grid analysis revealed that AlphaTrak2, OneTouch Ultra, Cerapet, and Optium Xceed were adequate, based on minimum accuracy criteria of ISO 15197:2013.

    Search related documents:
    Co phrase search for related documents
    • Bland Altman plotting and correlation analysis: 1
    • Bland Altman plotting and error grid: 1
    • Bland Altman plotting and error grid analysis: 1
    • blood glucose and cell volume: 1
    • blood glucose and correlation analysis: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • blood glucose and error grid: 1, 2, 3, 4, 5, 6, 7
    • blood glucose and error grid analysis: 1, 2, 3, 4
    • blood glucose and glucose concentration: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • blood glucose and glucose value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
    • blood glucose and high correlation: 1, 2
    • blood glucose and packed cell volume: 1
    • blood glucose value and correlation analysis: 1, 2
    • blood glucose value and glucose value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • cell volume and decrease PCV packed cell volume: 1
    • cell volume and error grid: 1
    • cell volume and error grid analysis: 1
    • cell volume and packed cell volume: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • correlation analysis and error grid: 1
    • correlation analysis and error grid analysis: 1