Selected article for: "acid solution and serum sample"

Author: TERAMICHI, Takurou; FUKUSHI, Shuetsu; HACHIYA, Yuma; MELAKU, Simenew Keskes; OGUMA, Keisuke; SENTSUI, Hiroshi
Title: Evaluation of serological assays available in a biosafety level 2 laboratory and their application for survey of Middle East respiratory syndrome coronavirus among livestock in Ethiopia
  • Document date: 2019_11_5
  • ID: vijh6x1l_11
    Snippet: Synthetic S1 fragment of MERS-CoV was obtained from Sino Biolobical Inc. (Beijing, China) and used as the antigen [17] . ELISA microplates were coated with 50 µl of 50 ng/ml antigen per well at 4°C overnight, following which the wells were incubated with PBS containing 2% Block Ace and 0.05% Tween 20 for 2 hr at 37°C. Following the removal of blocking reagent, diluted serum samples were added and incubated for 1 hr at 37°C. After washing the .....
    Document: Synthetic S1 fragment of MERS-CoV was obtained from Sino Biolobical Inc. (Beijing, China) and used as the antigen [17] . ELISA microplates were coated with 50 µl of 50 ng/ml antigen per well at 4°C overnight, following which the wells were incubated with PBS containing 2% Block Ace and 0.05% Tween 20 for 2 hr at 37°C. Following the removal of blocking reagent, diluted serum samples were added and incubated for 1 hr at 37°C. After washing the wells thrice with 0.05% Tween 20 in PBS (PBS-T), a peroxidase-labeled protein AG (Thermo Fisher Scientific, Waltham, MA, U.S.A.) was added and incubated for 1 hr at 37°C. Following further washing thrice with PBS-T, 100 µl of 2,2′-azinobis-3-ethylbenzthiazolinesulfonic acid (ABTS) substrate solution (Roche Applied Science, Penzberg, Germany) was added and incubated for 20 min at room temperature. The optical density (O.D.) of each well was measured at 450 nm using a microplate reader, and mean absorbance was determined for each serum sample. One of camel serum that showed a high antibody titer in the neutralization test by live MERS-CoV was treated as a positive control.

    Search related documents:
    Co phrase search for related documents
    • microplate reader and positive control: 1, 2, 3, 4, 5, 6
    • microplate reader and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
    • neutralization test and optical density: 1, 2, 3
    • neutralization test and positive control: 1, 2, 3, 4, 5, 6, 7, 8
    • neutralization test and room temperature: 1
    • neutralization test and S1 fragment: 1
    • neutralization test and serum sample: 1, 2, 3, 4, 5, 6, 7
    • optical density and positive control: 1, 2, 3, 4, 5
    • optical density and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
    • optical density and serum sample: 1, 2, 3, 4, 5
    • optical density and substrate solution: 1, 2, 3, 4, 5, 6
    • positive control and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
    • positive control and S1 fragment: 1
    • positive control and serum sample: 1, 2, 3, 4, 5, 6, 7
    • positive control and substrate solution: 1, 2, 3
    • room temperature and serum sample: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • room temperature and substrate solution: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • S1 fragment and Synthetic MERS CoV S1 fragment: 1
    • serum sample and substrate solution: 1, 2, 3