Selected article for: "flow cytometric analysis and fluorescein isothiocyanate"

Author: Bian, Qian; Lu, Jing; Zhang, Li; Chi, Ying; Li, Yan; Guo, Hongxiong
Title: Highly pathogenic avian influenza A virus H5N1 non-structural protein 1 is associated with apoptotic activation of the intrinsic mitochondrial pathway
  • Document date: 2017_8_28
  • ID: s6kpewt6_10
    Snippet: Flow cytometric analysis. In order to determine the apoptotic rate, ~1x10 6 NCI-H292 cells/ml were stained with fluorescein isothiocyanate (FITC)-conjugated Annexin V and propidium iodide (556547, Annexin V-FITC apoptosis detection kit, BD Pharmingen; BD Biosciences) in a volume of 100 µl on ice for 30 min in the dark. The cells were washed 3 times with PBS. Finally, 400 µl binding buffer was added to the cells. Additionally, the mixture was an.....
    Document: Flow cytometric analysis. In order to determine the apoptotic rate, ~1x10 6 NCI-H292 cells/ml were stained with fluorescein isothiocyanate (FITC)-conjugated Annexin V and propidium iodide (556547, Annexin V-FITC apoptosis detection kit, BD Pharmingen; BD Biosciences) in a volume of 100 µl on ice for 30 min in the dark. The cells were washed 3 times with PBS. Finally, 400 µl binding buffer was added to the cells. Additionally, the mixture was analyzed with a BD FACSCalibur flow cytometer and the percentage of apoptosis of 10,000 cells was determined. The data were analyzed using BD CellQuest™ Pro software (version 5.2.1; BD Biosciences) and the percentage cells with apoptosis per group were calculated.

    Search related documents:
    Co phrase search for related documents
    • µl 100 volume and flow cytometer: 1
    • µl 100 volume and flow cytometric analysis: 1
    • apoptosis detection and cell apoptosis: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • apoptosis detection and cytometric analysis: 1
    • apoptosis detection and flow cytometer: 1, 2
    • apoptosis detection and flow cytometric analysis: 1
    • apoptosis detection and group apoptosis: 1, 2
    • apoptosis detection kit and cell apoptosis: 1, 2, 3, 4
    • apoptosis detection kit and flow cytometer: 1
    • apoptotic rate and cell apoptosis: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • apoptotic rate and cell apoptosis percentage: 1
    • apoptotic rate and percentage cell: 1
    • BD CellQuest Pro software and BD facscalibur: 1, 2
    • BD facscalibur and cytometric analysis: 1
    • BD facscalibur and flow cytometer: 1, 2, 3, 4, 5
    • BD facscalibur and flow cytometric analysis: 1
    • BD facscalibur and fluorescein isothiocyanate: 1, 2, 3
    • BD facscalibur flow cytometer and flow cytometer: 1, 2, 3, 4, 5
    • BD facscalibur flow cytometer and fluorescein isothiocyanate: 1