Author: Kim, Jang Su; Lim, Chae Seung; Kim, Young Kee; Lee, Kap No; Lee, Chang Kyu
Title: Human Bocavirus in Patients with Respiratory Tract Infection Document date: 2011_6_28
ID: vuvgvz4n_9
Snippet: Real-time PCR for viral load was performed on the specimens positive for HBoV by conventional PCR. A TaqMan probe (5´-ATGTTGCCGCCAGTAACTCCACCC-3´) was labeled at the 5´ ends with the reporter molecule FAM and at the 3´ ends with Black Hole Quencher 1 (Biosearch Technologies, Inc., Novato, CA, USA). The assay was performed using Rotor-Gene 6000 (Corbett Life Science, Sydney, Australia) and the standard protocol of TaqMan universal PCR master m.....
Document: Real-time PCR for viral load was performed on the specimens positive for HBoV by conventional PCR. A TaqMan probe (5´-ATGTTGCCGCCAGTAACTCCACCC-3´) was labeled at the 5´ ends with the reporter molecule FAM and at the 3´ ends with Black Hole Quencher 1 (Biosearch Technologies, Inc., Novato, CA, USA). The assay was performed using Rotor-Gene 6000 (Corbett Life Science, Sydney, Australia) and the standard protocol of TaqMan universal PCR master mix (Applied Biosystems, Foster City, CA, USA); each 25 µL sample of the reaction mixture contained 10 pg/ µL of the forward and the reverse primers and 3 µL of the extracted DNA. Amplification conditions consisted of reactions for 3 min at 50˚C, 3 min at 94˚C, and 40 cycles of 30 sec at 94˚C, 30 sec at 60˚C and 30 sec at 72˚C maintained for 3 min. Detection limit of real-time PCR for HBoV was 1.3 × 10 3 copies/mL, which corresponded to 33 copies per reaction.
Search related documents:
Co phrase search for related documents- reaction mixture sample and real time: 1
- reaction mixture sample and real time pcr: 1
- real time and reverse primer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40
- real time and standard protocol: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
- real time and TaqMan probe: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43
- real time and viral load: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75
- real time and viral load real time pcr: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40
- real time pcr and reverse primer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37
- real time pcr and standard protocol: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- real time pcr and TaqMan probe: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39
- real time pcr and viral load: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74
- real time pcr and viral load real time pcr: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40
- reverse primer and standard protocol: 1
- reverse primer and TaqMan probe: 1, 2, 3
- reverse primer and viral load: 1, 2, 3
- standard protocol and viral load: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- standard protocol and viral load real time pcr: 1, 2
- TaqMan probe and viral load: 1, 2, 3, 4, 5, 6, 7, 8
- TaqMan probe and viral load real time pcr: 1, 2
Co phrase search for related documents, hyperlinks ordered by date