Author: Neethirajan, Suresh; Ahmed, Syed Rahin; Chand, Rohit; Buozis, John; Nagy, Éva
Title: Recent Advances in Biosensor Development for Foodborne Virus Detection Document date: 2017_7_5
ID: sj6zfybb_102
Snippet: Several novel biosensors have been developed in the detection of hepatitis B viruses based on impedimetric genosensor, plasmonic biosensor, and electrochemical immunosensor techniques. An impedimetric genosensor is developed using zeolite nanocrystals and multiwalled carbon nanotubes to detect PCR amplified single-stranded virus DNA [109] . The DNA hybridisation is detected as the nanocrystals are placed on a glass electrode constructed from fluo.....
Document: Several novel biosensors have been developed in the detection of hepatitis B viruses based on impedimetric genosensor, plasmonic biosensor, and electrochemical immunosensor techniques. An impedimetric genosensor is developed using zeolite nanocrystals and multiwalled carbon nanotubes to detect PCR amplified single-stranded virus DNA [109] . The DNA hybridisation is detected as the nanocrystals are placed on a glass electrode constructed from fluorine doped tin oxide, while the nanotubes are incorporated to enhance electro-conductivity. The detection results are compared to RT-PCR detection with 97% accuracy; and the sensitivity of detection limit is 50 copies/mL. The electrode can be reused by dipping in 0.1 M NaOH for three minutes with a loss of its initial activity as 50% in four weeks.
Search related documents:
Co phrase search for related documents- carbon nanotube and detection limit sensitivity: 1, 2, 3, 4
- carbon nanotube and single strand: 1
- detection limit and electro conductivity: 1
- detection limit and glass electrode: 1
- detection limit and novel biosensor: 1, 2, 3, 4, 5, 6, 7, 8, 9
- detection limit and PCR detect: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58
- detection limit and RT PCR detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73
- detection limit and single strand: 1, 2, 3
- detection limit and tin oxide: 1, 2, 3, 4, 5, 6, 7, 8, 9
- detection limit and virus dna: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
- detection limit sensitivity and novel biosensor: 1
- detection limit sensitivity and PCR detect: 1, 2, 3, 4, 5, 6
- detection limit sensitivity and RT PCR detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- detection limit sensitivity and tin oxide: 1
- detection limit sensitivity and virus dna: 1
- detection result and novel biosensor: 1
- detection result and PCR detect: 1, 2
- detection result and RT PCR detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- detection result and single strand: 1
Co phrase search for related documents, hyperlinks ordered by date