Author: Neethirajan, Suresh; Ahmed, Syed Rahin; Chand, Rohit; Buozis, John; Nagy, Éva
Title: Recent Advances in Biosensor Development for Foodborne Virus Detection Document date: 2017_7_5
ID: sj6zfybb_52
Snippet: In non-plasmonic systems, nanomaterials can functionalized with fluorescent labels and use as fluorescent probes rather than plasmonic probes. Non-plasmonic probes consider smaller metal nanoclusters, such as Ag nanoclusters with red or near-infrared fluorescent labels, for use as a probe. Such smaller metal nanoclusters can be stabilised by nucleic acid strands binding on a graphene oxide sheet. Other non-plasmonic nanomaterials are also used, s.....
Document: In non-plasmonic systems, nanomaterials can functionalized with fluorescent labels and use as fluorescent probes rather than plasmonic probes. Non-plasmonic probes consider smaller metal nanoclusters, such as Ag nanoclusters with red or near-infrared fluorescent labels, for use as a probe. Such smaller metal nanoclusters can be stabilised by nucleic acid strands binding on a graphene oxide sheet. Other non-plasmonic nanomaterials are also used, such as BaGdF5:Yd/Er NPs conjugated oligonucleotide with target linked Au nanoparticles, immunomagnitic nanobeads with biometallisation and electrochemistry features to detect viruses of 0.011 ng/mL [49] . Nanomaterial-based technology in virus detection involves two steps: isolation and capture of target viral molecules from the sample, and recognition and enhancement of the signals. Signal detection of nanomaterials includes optical and electrochemical approaches [51] . Optical detection with fluorescent properties is highly sensitive with low detection limits. Electrochemical detection, compared to optical detection, is often used with graphene or carbon nanotubes.
Search related documents:
Co phrase search for related documents- capture isolation and detection limit: 1
- carbon nanotube and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9
- carbon nanotube and electrochemical detection: 1, 2
- carbon nanotube and low detection limit: 1
- carbon nanotube graphene and detection limit: 1
- detection limit and electrochemical detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- detection limit and fluorescent label: 1
- detection limit and fluorescent probe: 1, 2, 3, 4, 5, 6, 7
- detection limit and low detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- electrochemical detection and low detection limit: 1, 2, 3, 4, 5
- fluorescent probe and low detection limit: 1
Co phrase search for related documents, hyperlinks ordered by date