Selected article for: "detection limit and ng detection limit"

Author: Neethirajan, Suresh; Ahmed, Syed Rahin; Chand, Rohit; Buozis, John; Nagy, Éva
Title: Recent Advances in Biosensor Development for Foodborne Virus Detection
  • Document date: 2017_7_5
  • ID: sj6zfybb_99
    Snippet: Electrochemical immunosensors are applied to hepatitis virus detection, and one of them is a chip-based device immobilizing anti-virus antibodies onto an electrochemical biosensor using protein A and nanogold particles as matrices [106] . The label-free device can capture five types of antigens from hepatitis viruses simultaneously, such as hepatitis A, B, C, D, and E viruses, as a one-step assay within 5 minutes. It uses a POC 2-electrode system.....
    Document: Electrochemical immunosensors are applied to hepatitis virus detection, and one of them is a chip-based device immobilizing anti-virus antibodies onto an electrochemical biosensor using protein A and nanogold particles as matrices [106] . The label-free device can capture five types of antigens from hepatitis viruses simultaneously, such as hepatitis A, B, C, D, and E viruses, as a one-step assay within 5 minutes. It uses a POC 2-electrode system to capture the virus antigens based on the molecular change prior to and post the antigen-antibody reaction with a detection limit of 1.0 ng/mL.

    Search related documents:
    Co phrase search for related documents
    • antigen antibody and ng detection limit: 1, 2, 3, 4, 5
    • antigen antibody and step assay: 1
    • antigen antibody and virus antigen: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • antigen antibody and virus antigen capture: 1
    • antigen antibody reaction and ng detection limit: 1, 2
    • antigen antibody reaction and virus antigen: 1, 2, 3, 4
    • antigen type and virus antigen: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • detection limit and ng detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • detection limit and POC system: 1, 2
    • detection limit and step assay: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • detection limit and virus antigen: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
    • detection limit and virus antigen capture: 1
    • electrochemical biosensor and ng detection limit: 1, 2
    • electrochemical biosensor and step assay: 1
    • electrochemical biosensor and virus antigen: 1
    • electrochemical immunosensor and ng detection limit: 1, 2, 3, 4
    • electrochemical immunosensor and virus antigen: 1
    • hepatitis virus and ng detection limit: 1, 2, 3
    • hepatitis virus and step assay: 1, 2, 3, 4