Author: Neethirajan, Suresh; Ahmed, Syed Rahin; Chand, Rohit; Buozis, John; Nagy, Éva
                    Title: Recent Advances in Biosensor Development for Foodborne Virus Detection  Document date: 2017_7_5
                    ID: sj6zfybb_105
                    
                    Snippet: Another electrochemical immnosensor is designed to detect hepatitis B virus surface antigen-antibody reaction using a double-deck gold film with thionine unites and platinum nanovire inlaid globular SBA-15 as an electrical probe [111] . The design can reduce the spatial limitations of loading secondary antibodies, provide pore accessibility of guest species from outside, and offer catalytically active sites on a large scale. The presence of thion.....
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: Another electrochemical immnosensor is designed to detect hepatitis B virus surface antigen-antibody reaction using a double-deck gold film with thionine unites and platinum nanovire inlaid globular SBA-15 as an electrical probe [111] . The design can reduce the spatial limitations of loading secondary antibodies, provide pore accessibility of guest species from outside, and offer catalytically active sites on a large scale. The presence of thionine enhances the electrical conductivity between the gold film and the nanowire to facilitate linear detection with a detection limit of 3.3 fM.
 
  Search related documents: 
                                Co phrase  search for related documents- antigen antibody and large scale: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
  - antigen antibody and secondary antibody: 1, 2, 3, 4, 5, 6, 7, 8, 9
  - antigen antibody reaction and detection limit: 1, 2, 3, 4, 5
  - antigen antibody reaction and secondary antibody: 1, 2
  - detection limit and electrical conductivity: 1, 2
  - detection limit and gold film: 1, 2, 3, 4
  - detection limit and large scale: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35
  - detection limit and linear detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39
  - detection limit and secondary antibody: 1, 2, 3
  - electrical conductivity and large scale: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date