Author: Qin, Jian; Jones, Robert C.; Ramakrishnan, Ramesh
Title: Studying copy number variations using a nanofluidic platform Document date: 2008_8_18
ID: prsvv6l9_22
Snippet: These large structural changes can be detected using conventional technologies such as Southern blot and longrange PCR. However, it is believed that real-time PCR is Figure 1 . Quantitation of the RPP30 copy number in spike-in samples that contain two to seven copies of the RPP30 molecules per two haploid genomes. The x-axis shows the expected ratio of the numbers of RPP30 molecules to RNase P molecules. The y-axis shows the observed ratios. Each.....
Document: These large structural changes can be detected using conventional technologies such as Southern blot and longrange PCR. However, it is believed that real-time PCR is Figure 1 . Quantitation of the RPP30 copy number in spike-in samples that contain two to seven copies of the RPP30 molecules per two haploid genomes. The x-axis shows the expected ratio of the numbers of RPP30 molecules to RNase P molecules. The y-axis shows the observed ratios. Each value is calculated using five panels of the same sample mix and the error bars represent standard errors. A good linear correlation can be seen with a coefficient of determination (R 2 ) of 0.996. currently the only promising technique that is able to provide information about the exact copy number of the CYP2D6 gene in a routine clinical setting (32) (33) (34) .
Search related documents:
Co phrase search for related documents- clinical setting and copy number: 1, 2, 3
- clinical setting and linear correlation: 1
- clinical setting and observed ratio: 1
- clinical setting and promising technique: 1
- clinical setting and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- clinical setting and routine clinical setting: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- conventional technology and linear correlation: 1
- conventional technology and real time: 1, 2, 3, 4, 5, 6
- copy number and good linear correlation: 1
- copy number and haploid genome: 1, 2
- copy number and linear correlation: 1, 2, 3, 4, 5, 6
- copy number and promising technique: 1
- copy number and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- expect ratio and observed ratio: 1
- good linear correlation and linear correlation: 1, 2, 3, 4, 5, 6, 7
- linear correlation and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- observed ratio and real time: 1, 2, 3, 4, 5, 6, 7
- promising technique and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9
- real time and sample mix: 1, 2, 3, 4, 5, 6
Co phrase search for related documents, hyperlinks ordered by date