Selected article for: "multiplex pcr and simplex PCR"

Author: PIEWBANG, Chutchai; RUNGSIPIPAT, Anudep; POOVORAWAN, Yong; TECHANGAMSUWAN, Somporn
Title: Development and application of multiplex PCR assays for detection of virus-induced respiratory disease complex in dogs
  • Document date: 2016_9_15
  • ID: w3g6ohac_22
    Snippet: Evaluation of the multiplex PCR using clinical specimens: The multiplex PCRs were tested on the 51 NS and 51 OS samples (Fig. 3) and compared with the simplex PCR assays for each respective virus ( Table 2 ). The CAdV-2 and CRCoV detection had 100% sensitivity and specificity for both the NS and OS sampling sites. False negative results were observed in CaHV-1, CIV, CPIV and CDV detection when performing multiplex PCRs, which resulted in a lower .....
    Document: Evaluation of the multiplex PCR using clinical specimens: The multiplex PCRs were tested on the 51 NS and 51 OS samples (Fig. 3) and compared with the simplex PCR assays for each respective virus ( Table 2 ). The CAdV-2 and CRCoV detection had 100% sensitivity and specificity for both the NS and OS sampling sites. False negative results were observed in CaHV-1, CIV, CPIV and CDV detection when performing multiplex PCRs, which resulted in a lower sensitivity of 87.5-97.7%. The PPV (100%) of all multiplex PCRs was consistent with the specificity (100%), while the NPV (89.5-99.0%) of those reactions was contrary with their sensitivity. Neither the multiplex RT-PCR nor the multiplex PCR showed false positive results when compared with its simplex counterpart.

    Search related documents:
    Co phrase search for related documents
    • clinical specimen and multiplex pcr: 1, 2, 3, 4, 5, 6
    • clinical specimen and negative result: 1, 2
    • clinical specimen and PCR assay: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • clinical specimen and positive result: 1
    • clinical specimen and sampling site: 1
    • clinical specimen and specificity 100 sensitivity: 1, 2, 3, 4
    • crcov detection and low sensitivity: 1
    • crcov detection and multiplex pcr: 1, 2, 3, 4, 5
    • crcov detection and os sample: 1
    • crcov detection and PCR assay: 1, 2, 3
    • crcov detection and specificity 100 sensitivity: 1
    • false negative result and low sensitivity: 1
    • false negative result and low sensitivity result: 1
    • false negative result and multiplex pcr: 1
    • false negative result and negative result: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75
    • false negative result and PCR assay: 1, 2, 3, 4, 5, 6, 7, 8
    • false negative result and positive result: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
    • false negative result and specificity 100 sensitivity: 1
    • false positive result and low sensitivity: 1, 2, 3