Selected article for: "gene target and MERS cov"

Author: Seong, Moon-Woo; Lee, Seung Jun; Cho, Sung Im; Ko, Kyungphil; Kim, Mi-Na; Sung, Heungsub; Kim, Jae-Seok; Ahn, Ji Soo; Yu, Byung Su; Kim, Taek Soo; Kim, Eui Chong; Park, Sung Sup
Title: External Quality Assessment of MERS-CoV Molecular Diagnostics During the 2015 Korean Outbreak
  • Document date: 2015_2_23
  • ID: uiou7c2b_24
    Snippet: In this survey, most participants used commercial rRT-PCR kits. Our results showed that significantly different CT values could be produced depending on the kit used. Though these kits are for semi-quantitative purposes and a difference in CT values does not correlate with differences in analytical sensitivity, a large difference in the CT values for the same material may influence the analytical sensitivity of the kit. Therefore, cut-off values .....
    Document: In this survey, most participants used commercial rRT-PCR kits. Our results showed that significantly different CT values could be produced depending on the kit used. Though these kits are for semi-quantitative purposes and a difference in CT values does not correlate with differences in analytical sensitivity, a large difference in the CT values for the same material may influence the analytical sensitivity of the kit. Therefore, cut-off values should be carefully validated for each method in order to have optimal sensitivity for the detection of MERS-CoV in clinical settings. In addition, our study demonstrates that CT values might be different depending on the platform used for performing real-time PCR, even when using the same commercial kit. Therefore, the platform as well as the kit should be considered when establishing or validating the cut-off value of a kit. It is known that the analytical sensitivity of MERS-CoV RT-PCR depends on the target gene tested; the ORF1a assay has a lower sensitivity compared with the upE assay [3] . In this survey, all participants reported both upE and ORF1a results. Both assays gave comparable results, and no significant difference between them was observed.

    Search related documents:
    Co phrase search for related documents
    • analytical sensitivity and CT value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • analytical sensitivity and cut value: 1, 2, 3, 4, 5, 6
    • analytical sensitivity and kit analytical sensitivity: 1, 2, 3, 4, 5, 6
    • clinical setting and commercial kit: 1
    • clinical setting and CT value: 1, 2, 3
    • clinical setting and cut value: 1, 2, 3
    • commercial kit and CT value: 1, 2
    • commercial kit and cut value: 1
    • commercial rrt pcr kit and CT value: 1
    • commercial rrt pcr kit and cut value: 1
    • CT value and cut value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • CT value and kit cut value: 1, 2
    • cut value and kit cut value: 1, 2, 3, 4, 5