Author: Zhang, Tie-Gang; Li, Ai-Hua; Lyu, Min; Chen, Meng; Huang, Fang; Wu, Jiang
Title: Detection of respiratory viral and bacterial pathogens causing pediatric community-acquired pneumonia in Beijing using real-time PCR Document date: 2015_7_7
ID: x91sayto_23
Snippet: In this study, we used commercially available multiplex real-time PCR kits to detect respiratory pathogens in pediatric CAP patients. The kits were able to detect 16 respiratory viruses and two bacteria. We compared the specificity and sensitivity of this kit with singleplex conventional PCR 16 and a commercial multiplex conventional PCR kit (Seeplex ® RV15 ACE Detection kit, Seegene, South Korea) using 73 throat swab specimens from upper respir.....
Document: In this study, we used commercially available multiplex real-time PCR kits to detect respiratory pathogens in pediatric CAP patients. The kits were able to detect 16 respiratory viruses and two bacteria. We compared the specificity and sensitivity of this kit with singleplex conventional PCR 16 and a commercial multiplex conventional PCR kit (Seeplex ® RV15 ACE Detection kit, Seegene, South Korea) using 73 throat swab specimens from upper respiratory tract infection cases. The positive factor numbers of singleplex conventional PCR, conventional multiplex PCR and multiplex real-time PCR were 56, 41 and 87, respectively (Data not published). The factors detected only by the multiplex real-time PCR assay were confirmed using previously published methods. 17 Using the multiplex real-time PCR assay the etiological agents could be identified within three hours of receiving the clinical samples. We chose to use the multiplex assay for its sensitivity, specify, and rapidity of the results.
Search related documents:
Co phrase search for related documents- ACE Detection kit and kit sensitivity specificity: 1, 2, 3
- ACE Detection kit and multiplex assay: 1, 2, 3, 4
- ACE Detection kit and multiplex real time PCR assay: 1
- ACE Detection kit and multiplex real time PCR kit: 1, 2
- ACE Detection kit and PCR assay: 1, 2, 3, 4
- ACE Detection kit and PCR kit: 1, 2, 3, 4, 5
- clinical sample and conventional PCR kit: 1
- clinical sample and Detection kit: 1, 2, 3, 4, 5
- clinical sample and etiological agent: 1, 2, 3, 4
- clinical sample and factor number: 1
- clinical sample and multiplex assay: 1, 2, 3, 4, 5, 6, 7
- clinical sample and multiplex real time PCR assay: 1
- clinical sample and PCR assay: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23
- clinical sample and PCR kit: 1, 2, 3, 4, 5, 6, 7, 8
- conventional PCR kit and Detection kit: 1, 2
- conventional PCR kit and multiplex assay: 1, 2
- conventional PCR kit and multiplex conventional PCR kit: 1, 2
- conventional PCR kit and multiplex real time PCR assay: 1
- conventional PCR kit and PCR assay: 1, 2
Co phrase search for related documents, hyperlinks ordered by date