Selected article for: "high specificity and PCR reaction"

Author: Pérez-Ruiz, Mercedes; Pedrosa-Corral, Irene; Sanbonmatsu-Gámez, Sara; Navarro-Marí, José-María
Title: Laboratory Detection of Respiratory Viruses by Automated Techniques
  • Document date: 2012_11_30
  • ID: ted64zo4_49
    Snippet: Other automated detection formats have been used for RV NAAT, as Respifinder ® 15 assay (PathoFinder) and Seeplex ® RV15 (Seegene). Both detect 15 viral pathogens in respiratory samples. The former is based on a multiplex RT-PCR followed a MLPA reaction, which comprises a probe hybridization step, a probe ligation step and a probe amplification step. Only two primers are used in the final PCR. Every target results in a PCR fragment of a specifi.....
    Document: Other automated detection formats have been used for RV NAAT, as Respifinder ® 15 assay (PathoFinder) and Seeplex ® RV15 (Seegene). Both detect 15 viral pathogens in respiratory samples. The former is based on a multiplex RT-PCR followed a MLPA reaction, which comprises a probe hybridization step, a probe ligation step and a probe amplification step. Only two primers are used in the final PCR. Every target results in a PCR fragment of a specific length [45] . Seeplex ® RV15 uses dual-priming oligonucleotides that allow multiplex PCR of high specificity and minimizes the possibility of unspecific DNA products. Detection of amplicons is accomplished by capillary electrophoresis with both assays [46] . Although these systems do not avoid the potential of contamination with amplicons, they are able to detect a wide range of RV at a lower cost. However, specific instruments for capillary electrophoresis are available only in high-throughput laboratories.

    Search related documents:
    Co phrase search for related documents
    • amplicon detection and high throughput: 1, 2
    • amplicon detection and hybridization step: 1
    • amplicon detection and low cost: 1
    • capillary electrophoresis and detection format: 1
    • capillary electrophoresis and high specificity: 1, 2, 3
    • capillary electrophoresis and high throughput: 1, 2, 3, 4, 5, 6
    • capillary electrophoresis and low cost: 1
    • detection format and high specificity: 1, 2, 3, 4
    • detection format and high throughput: 1, 2, 3, 4, 5
    • detection format and high throughput laboratory: 1, 2
    • detection format and low cost: 1
    • dna product and high specificity: 1, 2, 3
    • dna product and high throughput: 1
    • final PCR and high specificity: 1, 2
    • final PCR and high throughput: 1, 2, 3, 4
    • high specificity and low cost: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • high throughput and low cost: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • high throughput and mlpa reaction: 1
    • high throughput laboratory and low cost: 1, 2