Author: Gorzalski, Andrew J.; Tian, Honglin; Laverdure, Chris; Morzunov, Sergey; Verma, Subhash C.; VanHooser, Stephanie; Pandori, Mark W.
Title: High-Throughput Transcription-mediated amplification on the Hologic Panther is a highly sensitive method of detection for SARS-CoV-2 Cord-id: 4lu1n0s7 Document date: 2020_6_10
ID: 4lu1n0s7
Snippet: BACKGROUND: As the demand for laboratory testing for SARS-CoV-2 increases, additional varieties of testing methodologies are being considered. While real time polymerase chain reaction (RT-PCR) has performed as the main method for virus detection, other methods are becoming available, including transcription mediated amplification (TMA). The Hologic Aptima SARS-CoV-2 Assay utilizes TMA as a target amplification mechanism, and it has only recently received Emergency Use Authorization (EUA) by the
Document: BACKGROUND: As the demand for laboratory testing for SARS-CoV-2 increases, additional varieties of testing methodologies are being considered. While real time polymerase chain reaction (RT-PCR) has performed as the main method for virus detection, other methods are becoming available, including transcription mediated amplification (TMA). The Hologic Aptima SARS-CoV-2 Assay utilizes TMA as a target amplification mechanism, and it has only recently received Emergency Use Authorization (EUA) by the Food and Drug Administration (FDA). OBJECTIVES: We sought to compare the sensitivity and specificity of the Aptima SARS-CoV-2 Assay to RTPCR as a means of SARS-CoV-2 detection in a diagnostic setting. STUDY DESIGN: We performed a limit-of-detection study (LoD) to assess the analytical sensitivity of TMA and RT-PCR. This preceded a comparison of the methods using previously evaluated clinical specimens (nasopharyngeal swabs) using 116 human specimens tested by both methodologies. Specimens included sixty-one (61) specimens found reactive by real-time PCR, fifty-one (51) found non-reactive, and four (4) deemed inconclusive. RESULTS: The Aptima SARS-CoV-2 Assay showed a markedly higher analytical sensitivity than RT-PCR by LoD study. Evaluation of clinical specimens resulted in fewer inconclusive results by the SARS-CoV-2 assay, leading to potentially higher clinical sensitivity. CONCLUSIONS: The higher analytical sensitivity may explain the assay’s ability to ascertain for the presence of SARS-CoV-2 genome in human specimens deemed inconclusive by real-time PCR. TMA provides an effective, highly sensitive means of detection of SARS-CoV-2 in nasopharyngeal specimens.
Search related documents:
Co phrase search for related documents- additional benefit and low number: 1
- low number and lysis buffer: 1
Co phrase search for related documents, hyperlinks ordered by date