Author: Courtney R. Sullivan; Catharine A. Mielnik; Sinead M. O’Donovan; Adam J. Funk; Eduard Bentea; Erica A.K. DePasquale; Zhexing Wen; Vahram Haroutunian; Pavel Katsel; Amy J. Ramsey; Jarek Meller; Robert E. McCullumsmith
Title: Connectivity analyses of bioenergetic changes in schizophrenia: Identification of novel treatments Document date: 2018_6_5
ID: ltb6l5xz_113
Snippet: Nano liquid chromatography coupled electrospray tandem mass spectrometry (nLC-ESI-MS/MS) analyses were performed on a 5600+ QTOF mass spectrometer (Sciex, Toronto, On, Canada) interfaced to an Eksigent (Dublin, CA) nanoLC.ultra nanoflow system. Peptides were loaded (via an Eksigent nanoLC.as-2 autosampler) onto an IntegraFrit Trap Column (outer diameter of 360 µm, inner diameter of 100, and 25 µm packed bed) from New Objective, Inc. The copyrig.....
Document: Nano liquid chromatography coupled electrospray tandem mass spectrometry (nLC-ESI-MS/MS) analyses were performed on a 5600+ QTOF mass spectrometer (Sciex, Toronto, On, Canada) interfaced to an Eksigent (Dublin, CA) nanoLC.ultra nanoflow system. Peptides were loaded (via an Eksigent nanoLC.as-2 autosampler) onto an IntegraFrit Trap Column (outer diameter of 360 µm, inner diameter of 100, and 25 µm packed bed) from New Objective, Inc. The copyright holder for this preprint (which was not peer-reviewed) is the author/funder. It . https://doi.org/10.1101/338392 doi: bioRxiv preprint charge state of +2, high sensitivity mode, and rolling collision energy with a collision energy spread (CES) of 15 V was selected.
Search related documents:
Co phrase search for related documents- charge state and inner diameter: 1
- charge state and mass spectrometer: 1, 2, 3
- charge state and nanoflow system: 1
- collision energy and inner diameter: 1
- collision energy and liquid chromatography: 1, 2
- collision energy and mass spectrometer: 1, 2, 3, 4, 5
- collision energy and nanoflow system: 1
- high sensitivity and liquid chromatography: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- high sensitivity and mass spectrometer: 1
- inner diameter and mass spectrometer: 1
- inner diameter and nanoflow system: 1
- inner diameter and outer diameter: 1, 2, 3, 4, 5, 6, 7
- liquid chromatography and mass spectrometer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- liquid chromatography and Nano liquid chromatography: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- liquid chromatography and nanoflow system: 1
- mass spectrometer and Nano liquid chromatography: 1, 2
Co phrase search for related documents, hyperlinks ordered by date