Author: Jung, Kiwook; Shin, Sue; Nam, Minjeong; Hong, Yun Ji; Roh, Eun Youn; Park, Kyoung Un; Song, Eun Young
Title: Performance evaluation of three automated quantitative immunoassays and their correlation with a surrogate virus neutralization test in coronavirus disease 19 patients and preâ€pandemic controls Cord-id: m6b97t14 Document date: 2021_8_8
ID: m6b97t14
Snippet: BACKGROUND: SARSâ€CoVâ€2 pandemic is currently ongoing, meanwhile vaccinations are rapidly underway in some countries. The quantitative immunoassays detecting antibodies against spike antigen of SARSâ€CoVâ€2 have been developed based on the findings that they have a better correlation with the neutralizing antibody. METHODS: The performances of the Abbott Architect SARSâ€CoVâ€2 IgG II Quant, DiaSorin LIAISON SARSâ€CoVâ€2 TrimericS IgG, and Roche Elecsys antiâ€SARSâ€CoVâ€2 S were evalu
Document: BACKGROUND: SARSâ€CoVâ€2 pandemic is currently ongoing, meanwhile vaccinations are rapidly underway in some countries. The quantitative immunoassays detecting antibodies against spike antigen of SARSâ€CoVâ€2 have been developed based on the findings that they have a better correlation with the neutralizing antibody. METHODS: The performances of the Abbott Architect SARSâ€CoVâ€2 IgG II Quant, DiaSorin LIAISON SARSâ€CoVâ€2 TrimericS IgG, and Roche Elecsys antiâ€SARSâ€CoVâ€2 S were evaluated on 173 sera from 126 SARSâ€CoVâ€2 patients and 151 preâ€pandemic sera. Their correlations with GenScript cPass SARSâ€CoVâ€2 Neutralization Antibody Detection Kit were also analyzed on 173 sera from 126 SARSâ€CoVâ€2 patients. RESULTS: Architect SARSâ€CoVâ€2 IgG II Quant and Elecsys antiâ€SARSâ€CoVâ€2 S showed the highest overall sensitivity (96.0%), followed by LIAISON SARSâ€CoVâ€2 TrimericS IgG (93.6%). The specificities of Elecsys antiâ€SARSâ€CoVâ€2 S and LIAISON SARSâ€CoVâ€2 TrimericS IgG were 100.0%, followed by Architect SARSâ€CoVâ€2 IgG II Quant (99.3%). Regarding the correlation with cPass neutralization antibody assay, LIAISON SARSâ€CoVâ€2 TrimericS IgG showed the best correlation (Spearman rho = 0.88), followed by Architect SARSâ€CoVâ€2 IgG II Quant and Elecsys antiâ€SARSâ€CoVâ€2 S (all rho = 0.87). CONCLUSIONS: The three automated quantitative immunoassays showed good diagnostic performance and strong correlations with neutralization antibodies. These assays will be useful in diagnostic assistance, evaluating the response to vaccination, and the assessment of herd immunity in the future.
Search related documents:
Co phrase search for related documents- abbott architect and low sensitivity: 1, 2
Co phrase search for related documents, hyperlinks ordered by date