Selected article for: "positive test and test performance"

Author: Michel, Wiebke; Färber, Jacqueline; Dilas, Milica; Heuft, Hans-Gert; Tammer, Ina; Baar, Jannik; Kaasch, Achim J.
Title: A combined oro-nasopharyngeal swab is more sensitive than mouthwash in detecting SARS-CoV-2 by a high-throughput PCR assay
  • Cord-id: 7rjytja8
  • Document date: 2021_3_18
  • ID: 7rjytja8
    Snippet: OBJECTIVES: The optimal diagnostic specimen to detect SARS-CoV-2 by PCR in the upper respiratory tract is unclear. Mouthwash fluid has been reported as an alternative to nasopharyngeal and oropharyngeal swabs. We compared mouthwash fluid with a combined oro-nasopharyngeal swab regarding test performance. METHODS: In a large refugee facility, we retested individuals with a previous positive test for SARS-CoV-2 and their quarantined close contacts. All individuals were asymptomatic at the time of
    Document: OBJECTIVES: The optimal diagnostic specimen to detect SARS-CoV-2 by PCR in the upper respiratory tract is unclear. Mouthwash fluid has been reported as an alternative to nasopharyngeal and oropharyngeal swabs. We compared mouthwash fluid with a combined oro-nasopharyngeal swab regarding test performance. METHODS: In a large refugee facility, we retested individuals with a previous positive test for SARS-CoV-2 and their quarantined close contacts. All individuals were asymptomatic at the time of testing. First, a mouthwash (gargling for at least 5 s) with sterile water was performed. Then, with a single flocked swab the back of the throat and subsequently the nasopharynx were sampled. Samples were inactivated and analysed on a Roche cobas 6800(®) system with the Roche SARS-CoV-2 test. RESULTS: Of 76 individuals, 39 (51%) tested positive for SARS-CoV-2 by oro-nasopharyngeal swab. Mouthwash detected 13 of 76 (17%) infections, but did not detect any additional infection. Samples that were positive in both tests, had lower cycle threshold (Ct)-values for oro-nasopharyngeal samples, indicating a higher virus concentration, compared to samples only positive in oro-nasopharyngeal swabs. CONCLUSION: Mouthwash is not as sensitive as combined oro-nasopharyngeal swab in detecting upper respiratory tract infection.

    Search related documents:
    Co phrase search for related documents
    • accurate rapid and low sensitivity show: 1
    • accurate rapid and lung disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • accurate rapid detection and low sensitivity: 1, 2, 3, 4
    • accurate rapid detection and lung disease: 1
    • low respiratory tract and lung disease: 1, 2, 3
    • low sensitivity and lung disease: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    Co phrase search for related documents, hyperlinks ordered by date