Author: Xia, Yang; Chen, Weixiang; Ren, Hongyi; Zhao, Jianping; Wang, Lihua; Jin, Rui; Zhou, Jiesen; Wang, Qiyuan; Yan, Fugui; Zhang, Bin; Lou, Jian; Wang, Shaobin; Li, Xiaomeng; Zhou, Jie; Xia, Liming; Jin, Cheng; Feng, Jianjiang; Li, Wen; Shen, Huahao
Title: A rapid screening classifier for diagnosing COVID-19 Cord-id: 03blhf3m Document date: 2021_1_9
ID: 03blhf3m
Snippet: Rationale: Coronavirus disease 2019 (COVID-19) has caused a global pandemic. A classifier combining chest X-ray (CXR) with clinical features may serve as a rapid screening approach. Methods: The study included 512 patients with COVID-19 and 106 with influenza A/B pneumonia. A deep neural network (DNN) was applied, and deep features derived from CXR and clinical findings formed fused features for diagnosis prediction. Results: The clinical features of COVID-19 and influenza showed different patte
Document: Rationale: Coronavirus disease 2019 (COVID-19) has caused a global pandemic. A classifier combining chest X-ray (CXR) with clinical features may serve as a rapid screening approach. Methods: The study included 512 patients with COVID-19 and 106 with influenza A/B pneumonia. A deep neural network (DNN) was applied, and deep features derived from CXR and clinical findings formed fused features for diagnosis prediction. Results: The clinical features of COVID-19 and influenza showed different patterns. Patients with COVID-19 experienced less fever, more diarrhea, and more salient hypercoagulability. Classifiers constructed using the clinical features or CXR had an area under the receiver operating curve (AUC) of 0.909 and 0.919, respectively. The diagnostic efficacy of the classifier combining the clinical features and CXR was dramatically improved and the AUC was 0.952 with 91.5% sensitivity and 81.2% specificity. Moreover, combined classifier was functional in both severe and non-serve COVID-19, with an AUC of 0.971 with 96.9% sensitivity in non-severe cases, which was on par with the computed tomography (CT)-based classifier, but had relatively inferior efficacy in severe cases compared to CT. In extension, we performed a reader study involving three experienced pulmonary physicians, artificial intelligence (AI) system demonstrated superiority in turn-around time and diagnostic accuracy compared with experienced pulmonary physicians. Conclusions: The classifier constructed using clinical and CXR features is efficient, economical, and radiation safe for distinguishing COVID-19 from influenza A/B pneumonia, serving as an ideal rapid screening tool during the COVID-19 pandemic.
Search related documents:
Co phrase search for related documents- absence presence and accuracy performance: 1, 2
- absence presence and acid confirm: 1
- absence presence and additional imaging: 1
- absence presence and loss function: 1, 2
- absence presence and low incidence: 1, 2
- absence presence and low quality: 1, 2, 3
- accuracy improve and additional imaging: 1
- accuracy improve and loss function: 1, 2, 3, 4
- accuracy improve and low incidence: 1
- accuracy improve and low quality: 1, 2, 3, 4, 5, 6, 7
- accuracy performance and loss function: 1, 2, 3, 4, 5
- accuracy performance and low incidence: 1
- accuracy performance and low quality: 1, 2, 3, 4
- accurate approach and low incidence: 1
- accurate approach and low quality: 1, 2
- additional imaging and low incidence: 1
- additional imaging and low quality: 1
- loss function and low incidence: 1
Co phrase search for related documents, hyperlinks ordered by date