Author: Yoda, Tomoko; Suzuki, Yasuhiko; Yamazaki, Kenji; Sakon, Naomi; Kanki, Masashi; Kase, Tetsuo; Takahashi, Kazuo; Inoue, Kiyoshi
Title: Application of a modified loopâ€mediated isothermal amplification kit for detecting Norovirus genogroups I and II Cord-id: 06vah7pq Document date: 2009_10_25
ID: 06vah7pq
Snippet: Norovirus is a major etiologic agent in worldwide outbreaks of gastroenteritis associated with food as well as personâ€toâ€person transmission. The ubiquitous nature of Norovirus necessitates simple and rapid detection methods with high accuracy and sensitivity. To this end, several investigators have evaluated the usefulness of commercial reverseâ€transcription loopâ€mediated isothermal amplification (RTâ€LAMP) kits for detecting Norovirus genogroups I (GI) and II (GII). In previous studie
Document: Norovirus is a major etiologic agent in worldwide outbreaks of gastroenteritis associated with food as well as personâ€toâ€person transmission. The ubiquitous nature of Norovirus necessitates simple and rapid detection methods with high accuracy and sensitivity. To this end, several investigators have evaluated the usefulness of commercial reverseâ€transcription loopâ€mediated isothermal amplification (RTâ€LAMP) kits for detecting Norovirus genogroups I (GI) and II (GII). In previous studies, the conventional Loopamp kit for Norovirus GII showed a relatively high detection rate, while that for Norovirus GI showed a relatively low detection rate. In the present study, clinical Norovirus specimens were used to compare the detection rate of a modified Loopamp kit for Norovirus GI with the rates of the conventional Loopamp kit for Norovirus GI and an “inâ€house†RTâ€LAMP GI primer set, methods which had a high detection rate. Results from the present study showed that the modified Loopamp kit for Norovirus GI had a higher detection rate for two viral genotypes (GI.3, GI.11). On comparison with an “inâ€house†GII primer set using genotype GII.4 viruses circulating recently, the detection rate by the Loopamp kit for Norovirus GII was found to be higher, with a 98% detection rate. These results indicate the applicability of the modified LAMP kit for GI and the conventional LAMP kit for GII for detection of Noroviruses in clinical samples. J. Med. Virol. 81:2072–2078, 2009. © 2009 Wileyâ€Liss, Inc.
Search related documents:
Co phrase search for related documents- additional primer and ma ipswich: 1
- additional primer and ma ipswich new england biolabs: 1
- adenovirus positive and low detection: 1
- loop primer and low detection: 1
- loop primer and ltd chemical: 1
- loop primer and ltd eiken chemical: 1
- loop primer and ltd eiken chemical amplification kit: 1
- loop primer and ma ipswich: 1
- loopamp assay and ltd chemical: 1
- loopamp assay and ltd eiken chemical: 1
- loopamp assay and ltd eiken chemical amplification kit: 1
- loopamp kit and ltd chemical: 1
- loopamp kit and ltd eiken chemical: 1
- loopamp kit and ltd eiken chemical amplification kit: 1
- loopamp real time turbidimeter and ltd chemical: 1
- loopamp real time turbidimeter and ltd eiken chemical: 1
- loopamp real time turbidimeter and ltd eiken chemical amplification kit: 1
Co phrase search for related documents, hyperlinks ordered by date