Selected article for: "method sensitivity and rapid detection"

Author: Romero-Gómez, María Pilar; López, Rosario López; Montes, Remedios González; Ruiz, Cristina Ots; Cuesta, Sara Hierro; Crespo, María Antonia Martín; García, Santos García
Title: Immunochromatographic test for detection of adenovirus from respiratory samples: Is it a real solution for pediatric emergency department?
  • Cord-id: 0oos87b1
  • Document date: 2013_10_3
  • ID: 0oos87b1
    Snippet: Rapid diagnosis of adenoviral respiratory infections is required in order to decide optimal treatment strategies. The adenovirus antigen immunochromatography Adeno Respiratory Card Letitest (Leti diagnostics, Barcelona, Spain), was evaluated versus the shell-vial culture and multiplex PCR (Clart Pneumovir Version 3.0, Genomica, Madrid, Spain), in nasopharyngeal washes and oropharyngeal swabs specimens from subjects with respiratory tract infections. Between April 2011 and November 2012, 224 pati
    Document: Rapid diagnosis of adenoviral respiratory infections is required in order to decide optimal treatment strategies. The adenovirus antigen immunochromatography Adeno Respiratory Card Letitest (Leti diagnostics, Barcelona, Spain), was evaluated versus the shell-vial culture and multiplex PCR (Clart Pneumovir Version 3.0, Genomica, Madrid, Spain), in nasopharyngeal washes and oropharyngeal swabs specimens from subjects with respiratory tract infections. Between April 2011 and November 2012, 224 patients were included. The IC Adeno Respiratory Card Letitest was positive for 77.9% (74 of 95) of patients diagnosed at bedside. Using multiplex-PCR as the reference standard, the overall sensitivity was 77.9% and the specificity was 73.6%. Taking shell-viral culture as the reference method, the Adeno Respiratory Card Letitest (Leti diagnostics, Barcelona, Spain) sensitivity and specificity values were 80.0% and 60.9%, respectively. Using RT-PCR (Clart Pneumovir Version 3.0, Genomica, Madrid, Spain) as the reference standard, the viral culture sensitivity was 53.2% and the specificity was 100%. The Adeno Respiratory Card Letitest (Leti diagnostics, Barcelona, Spain) assay could be a simple and rapid method for antigenic detection of adenovirus in pediatric respiratory samples although it would be necessary to improve the specificity and sensitivity of the test.

    Search related documents:
    Co phrase search for related documents
    • acid amplification and acute respiratory infection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • acid amplification and additional testing: 1, 2, 3, 4, 5, 6
    • acid amplification and adenovirus addition: 1
    • acid amplification and adenovirus bocavirus: 1
    • acid amplification and adenovirus enterovirus: 1
    • acid amplification and adenovirus influenza: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acid amplification and adenovirus metapneumovirus: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acid amplification and adenovirus parainfluenza: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acid amplification and adenovirus parainfluenza virus: 1, 2, 3, 4, 5, 6, 7, 8
    • acid amplification and adenovirus respiratory: 1, 2, 3, 4, 5, 6, 7, 8
    • acid amplification and adenovirus respiratory syncytial virus: 1, 2, 3, 4, 5, 6, 7, 8
    • acid amplification and adenovirus rhinovirus: 1, 2, 3, 4, 5
    • acid amplification and adenovirus testing: 1
    • acid amplification and long period: 1
    • acid amplification and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
    • acid amplification and low specific: 1, 2, 3
    • acid detection and acute phase: 1, 2, 3
    • acid detection and acute respiratory infection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
    • acid detection and additional testing: 1, 2, 3