Author: Dzimianski, John V.; Lorig-Roach, Nicholas; O’Rourke, Sara M.; Alexander, David L.; Kimmey, Jacqueline M.; DuBois, Rebecca M.
Title: Rapid and sensitive detection of SARS-CoV-2 antibodies by biolayer interferometry Cord-id: 2o3wosaz Document date: 2020_12_10
ID: 2o3wosaz
Snippet: Serological testing to evaluate antigen-specific antibodies in plasma is generally performed by rapid lateral flow test strips that lack quantitative results or by high complexity immunoassays that are time- and labor-intensive but provide semi-quantitative results. Here, we describe a novel application of biolayer interferometry for the rapid detection of antigen-specific antibody levels in plasma samples, and demonstrate its utility for quantification of SARS-CoV-2 antibodies. Our biolayer int
Document: Serological testing to evaluate antigen-specific antibodies in plasma is generally performed by rapid lateral flow test strips that lack quantitative results or by high complexity immunoassays that are time- and labor-intensive but provide semi-quantitative results. Here, we describe a novel application of biolayer interferometry for the rapid detection of antigen-specific antibody levels in plasma samples, and demonstrate its utility for quantification of SARS-CoV-2 antibodies. Our biolayer interferometry immunosorbent assay (BLI-ISA) utilizes single-use biosensors in an automated “dip-and-read†format, providing real-time optical measurements of antigen loading, plasma antibody binding, and antibody isotype detection. Complete semi-quantitative results are obtained in less than 20 min. BLI-ISA meets or exceeds the performance of high complexity methods such as Enzyme-Linked Immunosorbent Assay (ELISA) and Chemiluminescent Immunoassay. Importantly, our method can be immediately implemented on existing BLI platforms for urgent COVID-19 studies, such as serosurveillance and the evaluation of vaccine candidates. In a broader sense, BLI-ISA can be developed as a novel diagnostic platform to evaluate antibodies and other biomolecules in clinical specimens.
Search related documents:
Co phrase search for related documents- logistic regression and longitudinal study: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- logistic regression and low concentration: 1, 2, 3
- logistic regression and low percentage: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- logistic regression and low signal: 1
- logistic regression model and longitudinal study: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- logistic regression model and low percentage: 1
- longitudinal study and low percentage: 1, 2
Co phrase search for related documents, hyperlinks ordered by date