Selected article for: "acceptable sensitivity and acute respiratory"

Author: Manthei, David M; Whalen, Jason F; Schroeder, Lee F; Sinay, Anthony M; Li, Shih-Hon; Valdez, Riccardo; Giacherio, Donald A; Gherasim, Carmen
Title: Differences in Performance Characteristics Among Four High-Throughput Assays for the Detection of Antibodies Against SARS-CoV-2 Using a Common Set of Patient Samples
  • Cord-id: 1ix3n3k5
  • Document date: 2020_10_9
  • ID: 1ix3n3k5
    Snippet: OBJECTIVES: Serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has experienced a changing landscape of available assays coupled with uncertainty surrounding performance characteristics. Studies are needed to directly compare multiple commercially available assays. METHODS: Residual serum samples were identified based on SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) testing, clinical test results, and collection dates. Serum samples were analy
    Document: OBJECTIVES: Serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has experienced a changing landscape of available assays coupled with uncertainty surrounding performance characteristics. Studies are needed to directly compare multiple commercially available assays. METHODS: Residual serum samples were identified based on SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) testing, clinical test results, and collection dates. Serum samples were analyzed using assays from four different manufacturers: DiaSorin anti–SARS-CoV-2 S1/S2 IgG, EUROIMMUN anti–SARS-CoV-2 IgG ELISA, Roche Elecsys anti–SARS-CoV-2, and Siemens SARS-CoV-2 Total antibody assays. RESULTS: Samples from SARS-CoV-2 RT-PCR–positive patients became increasingly positive as time from symptom onset increased. For patients with latest sample 14 or more days after symptom onset, sensitivities reached 93.1% to 96.6%, 98.3%, and 96.6% for EUROIMMUN, Roche, and Siemens assays, respectively, which were superior to the DiaSorin assay at 87.7%. The specificity of Roche and Siemens assays was 100% and superior to DiaSorin and EUROIMMUN assays, which ranged from 96.1% to 97.0% and 86.3% to 96.4%, respectively. CONCLUSIONS: Laboratories should be aware of the advantages and limitations of serology testing options for SARS-CoV-2. The specificity and sensitivity achieved by the Roche and Siemens assays would be acceptable for testing in lower-prevalence regions and have the potential of orthogonal testing advantages if used in combination.

    Search related documents:
    Co phrase search for related documents
    • abbott realtime sars and low prevalence: 1
    • abbott realtime sars assay and low positive: 1
    • additional sample and low positive: 1, 2, 3
    • additional sample and low positive sample: 1
    • additional testing and low positive: 1, 2, 3
    • additional testing and low positive sample: 1
    • additional testing and low prevalence: 1, 2, 3