Selected article for: "present study and sensitivity specificity"

Author: Sadeghi, Somayeh; Golshani, Marjan; Safaeian, Bahareh
Title: New cut-off point for D-dimer in the diagnosis of pulmonary embolism during pregnancy.
  • Cord-id: 1eetpdhr
  • Document date: 2021_8_12
  • ID: 1eetpdhr
    Snippet: Background Considering that pulmonary embolism (PE) is one of the leading causes of mortality among pregnant women and that the D-dimer level in pregnancy can be highly fluctuating, a new and reliable Ddimer reference value is essential to identifying PE in this group of patients. Hence, the present study aimed to evaluate the diagnostic effect of D-dimer testing in pregnant women with suspected PE. Methods This study recruited 100 women with confirmed pregnancy or six weeks after delivery or ab
    Document: Background Considering that pulmonary embolism (PE) is one of the leading causes of mortality among pregnant women and that the D-dimer level in pregnancy can be highly fluctuating, a new and reliable Ddimer reference value is essential to identifying PE in this group of patients. Hence, the present study aimed to evaluate the diagnostic effect of D-dimer testing in pregnant women with suspected PE. Methods This study recruited 100 women with confirmed pregnancy or six weeks after delivery or abortion with suspected PE symptoms. Wells criteria, D-dimer values, and pregnancy trimesters were recorded. Definitive PE results were obtained using multidetector computed tomography (MDCT) or pulmonary ventilation/perfusion scans. Results D-dimer cut-off point in PE diagnosis was higher than 1,447 μg/L [sensitivity, 87.5%; specificity, 63.04%; area under the curve (AUC)=0.735; P=0.003]. In addition, the combination of Wells criteria with the D-dimer test indicated that the cut-off points of D-dimer in PE likely and unlikely women were 1,962 and 1,447 μg/L, respectively, and had acceptable and significant diagnostic value in PE detection. In addition, the diagnostic value of D-dimer in pregnancy trimesters was not found to be significant (P>0.05). Conclusion The new cut-off points of 1,447 and 1,962 μg/L were determined for D-dimer in pregnant women with likely and unlikely PE, respectively. Moreover, the new cut-off points in the first and second trimesters of pregnancy were 1,701 μg/L and 1,451 μg/L, respectively, which indicated no statistically acceptable diagnostic value.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date