Selected article for: "detection sensitivity and real time"

Author: Yan, Chao; Cui, Jinghua; Huang, Lei; Du, Bing; Chen, Lu; Xue, Guanhua; Li, Shaoli; Zhang, Weiwei; Zhao, Linqing; Sun, Yu; Yao, Hailan; Li, Nannan; Zhao, Hanqing; Feng, Yanling; Liu, Shiyu; Zhang, Qun; Liu, Di; Yuan, Jing
Title: Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay
  • Cord-id: 4m9p717r
  • Document date: 2020_4_8
  • ID: 4m9p717r
    Snippet: OBJECTIVE: To evaluate a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for detection of SARS-CoV-2, and compare it with RT polymerase chain reaction (RT-PCR). METHODS: We designed primers specific to the orf1ab and S genes of SARS-CoV-2. Total viral RNA was extracted using the QIAamp Viral RNA Mini Kit. We optimized the RT-LAMP assay. And, this assay was evaluated for its sensitivity and specificity of detection using real-time turbidity monitoring and visual obser
    Document: OBJECTIVE: To evaluate a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for detection of SARS-CoV-2, and compare it with RT polymerase chain reaction (RT-PCR). METHODS: We designed primers specific to the orf1ab and S genes of SARS-CoV-2. Total viral RNA was extracted using the QIAamp Viral RNA Mini Kit. We optimized the RT-LAMP assay. And, this assay was evaluated for its sensitivity and specificity of detection using real-time turbidity monitoring and visual observation. RESULTS: The primer sets orf1ab-4 and S-123 amplified the genes in the shortest times, the mean (±SD) time was 18 ± 1.32 min and 20 ± 1.80 min, respectively, and 63°C was the optimum reaction temperature. The sensitivity was 2×10(1) copies and 2×10(2) copies per reaction with primer sets orf1ab-4 and S-123, respectively. This assay showed no cross-reactivity with other 60 respiratory pathogens. To describe the availability of this method in clinical diagnosis, we collected 130 specimens from patients with clinically suspected SARS-CoV-2 infection. Among them, 58 were confirmed to be positive and 72 were negative by RT-LAMP. The sensiticity was 100% (95% CI 92.3% - 100%), specificity 100% (95% CI 93.7% - 100%). This assay detected SARS-CoV-2 in the mean (±SD) time of 26.28 ± 4.48 min and the results can be identified with visual observation. CONCLUSION: These results demonstrate that we developed a rapid, simple, specific, and sensitive RT-LAMP assay for SARS-CoV-2 detection among clinical samples. It will be a powerful tool for SARS-CoV-2 identification, and for monitoring suspected patients, close contacts, and high-risk groups.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1