Selected article for: "cc NC ND International license and double quencher probe"

Author: Yosuke Hirotsu; Hitoshi Mochizuki; Masao Omata
Title: Double-Quencher Probes Improved the Detection Sensitivity of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by One-Step RT-PCR
  • Document date: 2020_3_20
  • ID: 2gokv7id_23
    Snippet: We concluded that the double-quencher probe (ZEN/IBFQ) reduced the background signal and lowered the Ct value compared to the single-quencher probe (TAMRA). To this end, we analyzed the fluorescent signals during the cycles of RT-PCR at three independent experiments. As expected, the doublequencher probes decreased the background FAM fluorescent signals at the baseline ( Figure 3 ). The baseline fluorescent signal of the N1 site of NIID ranged fr.....
    Document: We concluded that the double-quencher probe (ZEN/IBFQ) reduced the background signal and lowered the Ct value compared to the single-quencher probe (TAMRA). To this end, we analyzed the fluorescent signals during the cycles of RT-PCR at three independent experiments. As expected, the doublequencher probes decreased the background FAM fluorescent signals at the baseline ( Figure 3 ). The baseline fluorescent signal of the N1 site of NIID ranged from 150×10 4 to 200×10 4 . However that of YCH was around or less than 50×10 4 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.

    Search related documents:
    Co phrase search for related documents
    • background signal and Ct value: 1, 2, 3
    • background signal and double quencher: 1, 2, 3, 4, 5, 6, 7, 8
    • background signal and double quencher probe: 1
    • background signal and FAM fluorescent: 1
    • background signal and fluorescent signal: 1, 2, 3, 4, 5
    • background signal and International license: 1, 2, 3
    • background signal and RT PCR cycle: 1, 2
    • background signal reduce and double quencher: 1, 2, 3
    • background signal reduce and FAM fluorescent: 1
    • cc NC ND International license and Ct value: 1, 2, 3, 4
    • cc NC ND International license and double quencher: 1
    • cc NC ND International license and double quencher probe: 1
    • cc NC ND International license and independent experiment: 1, 2
    • cc NC ND International license and International license: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • Ct value and double quencher: 1, 2, 3
    • Ct value and double quencher probe: 1
    • Ct value and fluorescent signal: 1, 2, 3, 4, 5
    • Ct value and International license: 1, 2, 3, 4, 5, 6, 7, 8
    • Ct value and N1 site: 1