Selected article for: "acid assay and acute respiratory syndrome"

Author: Ni, Minjun; Xu, Hengyi; Luo, Jie; Liu, Wei; Zhou, Donggen
Title: Simultaneous detection and differentiation of SARS-CoV-2, influenza A virus and influenza B virus by one-step quadruplex real-time RT-PCR in patients with clinical manifestations
  • Cord-id: 11s90h6x
  • Document date: 2020_12_14
  • ID: 11s90h6x
    Snippet: OBJECTIVE: To develop a novel quadruplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assay for the diagnosis of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, differential diagnosis and detection of co-infections. METHODS: A one-step quadruplex rRT-PCR assay was developed for simultaneous detection and differentiation of SARS-CoV-2 ORF1ab and N genes, influenza A virus (hIAV) and influenza B virus (hIBV). RESULTS: The quadruplex rRT-PCR assay had
    Document: OBJECTIVE: To develop a novel quadruplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assay for the diagnosis of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, differential diagnosis and detection of co-infections. METHODS: A one-step quadruplex rRT-PCR assay was developed for simultaneous detection and differentiation of SARS-CoV-2 ORF1ab and N genes, influenza A virus (hIAV) and influenza B virus (hIBV). RESULTS: The quadruplex rRT-PCR assay had good sensitivity and specificity. Correlation coefficients and amplification efficiencies of all singleplex and quadruplex rRT-PCR reactions were within acceptable ranges. The 95% lower limits of detection for plasmid standards and positive nucleic acid extracts of the quadruplex rRT-PCR assay were 57.38–95.11 copies/μL and 114.65–154.25 copies/μL, respectively. Excellent results were attained for inter- and intra-assay reproducibility. Among these clinical samples, only four samples showed results inconsistent with the singleplex rRT-PCR assays. CONCLUSIONS: To the authors’ knowledge, this is the first study to report a quadruplex rRT-PCR assay for the detection of two SARS-CoV-2 genes, hIAV and hIBV with perfect clinical performance.

    Search related documents:
    Co phrase search for related documents
    • accuracy sensitivity and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accuracy sensitivity and low concentration: 1, 2, 3
    • accuracy sensitivity and low concentration sample: 1
    • accuracy sensitivity excellent specificity and acute respiratory syndrome: 1
    • accurate diagnosis and acid extraction: 1, 2, 3, 4
    • accurate diagnosis and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate diagnosis and low concentration: 1, 2
    • accurate diagnosis and low concentration sample: 1
    • accurate fast and acid extraction: 1
    • accurate fast and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
    • acid extract and acute respiratory syndrome: 1, 2, 3, 4, 5, 6
    • acid extraction and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid extraction and low concentration: 1, 2, 3
    • acid extraction and low concentration sample: 1, 2
    • acute respiratory syndrome and loa agreement: 1
    • acute respiratory syndrome and low concentration: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acute respiratory syndrome and low concentration sample: 1
    • acute respiratory syndrome and lymphopenia leukopenia: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20