Author: Keshavarz, B.; Wiencek, J. R.; Workman, L. J.; Straesser, M. D.; Muehling, L. M.; Canderan, G.; Drago, F.; Bonham, C. A.; Sturek, J. M.; Ramani, C.; McNamara, C. A.; Woodfolk, J. A.; Kadl, A.; Platts-Mills, T. A. E.; Wilson, J. M.
Title: Quantitative measurement of IgG to SARS-CoV-2 proteins using ImmunoCAP Cord-id: 1a4qme84 Document date: 2020_11_12
ID: 1a4qme84
Snippet: Background: Detailed understanding of the immune response to SARS-CoV-2, the cause of coronavirus disease 2019 (COVID-19), has been hampered by a lack of quantitative antibody assays. Objective: To develop a quantitative assay for IgG to SARS-CoV-2 proteins that could readily be implemented in clinical and research laboratories. Methods: The biotin-streptavidin technique was used to conjugate SARS-CoV-2 spike receptor-binding-domain (RBD) or nucleocapsid protein to the solid-phase of the ImmunoC
Document: Background: Detailed understanding of the immune response to SARS-CoV-2, the cause of coronavirus disease 2019 (COVID-19), has been hampered by a lack of quantitative antibody assays. Objective: To develop a quantitative assay for IgG to SARS-CoV-2 proteins that could readily be implemented in clinical and research laboratories. Methods: The biotin-streptavidin technique was used to conjugate SARS-CoV-2 spike receptor-binding-domain (RBD) or nucleocapsid protein to the solid-phase of the ImmunoCAP resin. Plasma and serum samples from patients with COVID-19 (n=51) and samples from donors banked prior to the emergence of COVID-19 (n=109) were used in the assay. SARS-CoV-2 IgG levels were followed longitudinally in a subset of samples and were related to total IgG and IgG to reference antigens using an ImmunoCAP 250 platform. Results: Performance characteristics demonstrated 100% sensitivity and 99% specificity at a cut-off level of 2.5 g/mL for both SARS-CoV-2 proteins. Among 36 patients evaluated in a post-hospital follow-up clinic, median levels of IgG to spike-RBD and nucleocapsid were 34.7 g/mL (IQR 18-52) and 24.5 g/mL (IQR 9-59), respectively. Among 17 patients with longitudinal samples there was a wide variation in the magnitude of IgG responses, but generally the response to spike-RBD and to nucleocapsid occurred in parallel, with peak levels approaching 100 g/mL, or 1% of total IgG. Conclusions: We have described a quantitative assay to measure IgG to SARS-CoV-2 that could be used in clinical and research laboratories and implemented at scale. The assay can easily be adapted to measure IgG to novel antigens, has good performance characteristics and a read-out in standardized units.
Search related documents:
Co phrase search for related documents- abbott architect and longitudinal blood: 1
- abbott assay and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- abundant igg and acute respiratory syndrome coronavirus: 1, 2
- acute phase and longitudinal blood: 1, 2, 3, 4, 5
- acute phase and longitudinally follow: 1
- acute respiratory syndrome coronavirus and longitudinal blood: 1, 2, 3, 4, 5
- acute respiratory syndrome coronavirus and ma cambridge: 1
- ma cambridge abcam and ma waltham: 1
- ma cambridge and ma waltham: 1
Co phrase search for related documents, hyperlinks ordered by date