Selected article for: "air flow and isolation room"

Author: Cho, Jinkyun
Title: Investigation on the contaminant distribution with improved ventilation system in hospital isolation rooms: Effect of supply and exhaust air diffuser configurations
  • Cord-id: 2iqr8jzm
  • Document date: 2019_2_5
  • ID: 2iqr8jzm
    Snippet: This study, that is practice-based learning in a real hospital construction project, has evaluated the ventilation performance of three strategies in the protection of health care workers and HVAC control for airborne infectious diseases induced by contaminated exhaled air from patients in a negative pressure isolation room. This paper examines air flow path and airborne pollutant distribution by computational fluid dynamics modeling and field measurement. In hospitals, the risk of virus diffusi
    Document: This study, that is practice-based learning in a real hospital construction project, has evaluated the ventilation performance of three strategies in the protection of health care workers and HVAC control for airborne infectious diseases induced by contaminated exhaled air from patients in a negative pressure isolation room. This paper examines air flow path and airborne pollutant distribution by computational fluid dynamics modeling and field measurement. In hospitals, the risk of virus diffusion mainly depends on air flow behavior and changes in direction caused by supply air and exhaust air locations. An improved isolation room ventilation strategy has been suggested, and is found to be the most efficient in removing contaminants based on the observations and simulation results from three ventilation systems. The results show that ventilation systems utilizing the “low-level extraction” technique are very effective at removing pollutants in the human breathing zone. A new clean isolation room ventilation strategy has been developed that employs two exhaust air grilles on the wall behind the bed at low floor level, coupled with a fan filter unit, and is found to have the highest pollutant removal efficiency.

    Search related documents:
    Co phrase search for related documents
    • accurate reliable and additional analysis: 1
    • activity met and acute respiratory syndrome: 1
    • acute respiratory syndrome and additional analysis: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
    • acute respiratory syndrome and load condition: 1, 2, 3
    • acute respiratory syndrome and location monitor: 1
    • acute respiratory syndrome and location monitoring: 1
    • acute respiratory syndrome and location type: 1, 2, 3