                    Title: Drill splatter in orthopaedic procedures and its importance during the COVID-19 pandemic: an experimental study  Cord-id: 3rlgj3ot  Document date: 2021_9_7
                    ID: 3rlgj3ot
                    
                    Snippet: AIMS: During the COVID-19 pandemic, drilling has been classified as an aerosol-generating procedure. However, there is limited evidence on the effects of bone drilling on splatter generation. Our aim was to quantify the effect of drilling on splatter generation within the orthopaedic operative setting. METHODS: This study was performed using a Stryker System 7 dual rotating drill at full speed. Two fluid mediums (Videne (Solution 1) and Fluorescein (Solution 2)) were used to simulate drill splat
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: AIMS: During the COVID-19 pandemic, drilling has been classified as an aerosol-generating procedure. However, there is limited evidence on the effects of bone drilling on splatter generation. Our aim was to quantify the effect of drilling on splatter generation within the orthopaedic operative setting. METHODS: This study was performed using a Stryker System 7 dual rotating drill at full speed. Two fluid mediums (Videne (Solution 1) and Fluorescein (Solution 2)) were used to simulate drill splatter conditions. Drilling occurred at saw bone level (0 cm) and at different heights (20 cm, 50 cm, and 100 cm) above the target to simulate the surgeon ‘working arm length’, with and without using a drill guide. The furthest droplets were marked and the droplet displacement was measured in cm. A surgical microscope was used to detect microscopic droplets. RESULTS: Bone drilling produced 5 cm and 7 cm droplet displacement using Solutions 1 and 2, respectively. Drilling at 100 cm above the target produced the greatest splatter generation with a 95 cm macroscopic droplet displacement using Solution 2. Microscopic droplet generation was noticed at further distances than what can be macroscopically seen using Solution 1 (98 cm). Using the drill guide, there was negligible drill splatter generation. CONCLUSION: Our study has shown lower than anticipated drill splatter generation. The use of a drill guide acted as a protective measure and significantly reduced drill splatter. We therefore recommend using a drill guide at all times to reduce the risk of viral transmission in the operative setting. Cite this article: Bone Jt Open 2021;2(9):752–756.
 
  Search related documents: 
                                Co phrase  search for related documents- Try single phrases listed below for: 1
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date