Selected article for: "chain reaction and negative predictive value"

Author: Bulilete, Oana; Lorente, Patricia; Leiva, Alfonso; Carandell, Eugenia; Oliver, Antonio; Rojo, Estrella; Pericas, Pau; Llobera, Joan
Title: Panbioâ„¢ rapid antigen test for SARS-CoV-2 has acceptable accuracy in symptomatic patients in primary health care
  • Cord-id: 1vsvu7yy
  • Document date: 2021_2_13
  • ID: 1vsvu7yy
    Snippet: OBJECTIVES: We aimed to evaluate the accuracy of the Panbioâ„¢ Ag-RDT at primary health care (PHC) centers and test sites in symptomatic patients and close contacts, using the Reverse-Transcription Polymerase Chain Reaction (RT-PCR) test as the gold standard. METHODS: The study was conducted in four PHC centers and two test sites in Mallorca, Spain. Consecutive patients older than 18 years, attending the sites for RT-PCR testing were included. Two nasopharyngeal samples were collected, one for R
    Document: OBJECTIVES: We aimed to evaluate the accuracy of the Panbio™ Ag-RDT at primary health care (PHC) centers and test sites in symptomatic patients and close contacts, using the Reverse-Transcription Polymerase Chain Reaction (RT-PCR) test as the gold standard. METHODS: The study was conducted in four PHC centers and two test sites in Mallorca, Spain. Consecutive patients older than 18 years, attending the sites for RT-PCR testing were included. Two nasopharyngeal samples were collected, one for RT-PCR and the other was processed on-site using the Panbio™ rapid antigen test kit for SARS-CoV-2. The sensitivity and specificity were calculated using RT-PCR as the reference, and the predictive values using the pretest probability results for each analyzed group. FINDINGS: A total of 1369 participants were included; mean age 42.5 ± 14.9 years and 54.3% women. The overall prevalence was 10.2%. Most participants (70.6%) presented within 5 days of the onset of symptoms. The overall sensitivity was of 71.4% (95% CI: 63.1%, 78.7%), the specificity of 99.8% (95% CI: 99.4%, 99.9%), the positive predictive value of 98.0% (95% CI: 93.0%, 99.7%) and a negative predictive value of 96.8% (95% CI: 95.7%, 97.7%). The sensitivity was higher in symptomatic patients, in those arriving within 5 days since symptom onset and in those with high viral load. INTERPRETATION: Ag-RDT had relatively good performance characteristics in suspected symptomatic patients within five days since the onset of symptoms. However, our data do not support the sole use of Panbio™ Ag-RDT in asymptomatic individuals. FUNDING: None

    Search related documents:
    Co phrase search for related documents
    • active infection and low income: 1, 2, 3, 4, 5, 6, 7, 8
    • active infection and low income country: 1, 2
    • active infection and low sensitivity: 1, 2, 3
    • additional information and low income: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • additional information and low sensitivity: 1
    • long processing time and low sensitivity: 1