Selected article for: "acquisition mode and mass spectrometer"

Author: Qi Liu; Amita Gupta; Ayse Okesli-Armlovich; Wenjie Qiao; Curt R. Fischer; Mark Smith; Jan E. Carette; Michael C. Bassik; Chaitan Khosla
Title: Enhancing the Antiviral Efficacy of RNA-Dependent RNA Polymerase Inhibition by Combination with Modulators of Pyrimidine Metabolism
  • Document date: 2020_3_25
  • ID: 1zk64gsg_98
    Snippet: LC-MS/MS was performed on an Agilent 1290 infinity II LC system tandem with 6470 triple quad mass spectrometer using ion pairing chromatography. LC separation was performed at 40 ºC with a solvent flow rate of 0.25 mL/min on a Zorbax RRHD Extended-C18 column (2.1 × 150 mm, 1.8 µM). Buffer A contained 97% H2O, 3% MeOH, 5 mM tributylamine, 5.5 mM acetic acid and 1 µM medronic acid at pH=5.0;Buffer B contained ca. 100% MeOH, 5 mM tributylamine, .....
    Document: LC-MS/MS was performed on an Agilent 1290 infinity II LC system tandem with 6470 triple quad mass spectrometer using ion pairing chromatography. LC separation was performed at 40 ºC with a solvent flow rate of 0.25 mL/min on a Zorbax RRHD Extended-C18 column (2.1 × 150 mm, 1.8 µM). Buffer A contained 97% H2O, 3% MeOH, 5 mM tributylamine, 5.5 mM acetic acid and 1 µM medronic acid at pH=5.0;Buffer B contained ca. 100% MeOH, 5 mM tributylamine, 5.5 mM acetic acid and 10 µM medronic acid at pH=7.0 The initial mobile phase composition was 100% solvent A, and the gradient (%B) after sample injection was as follows: 0% at 2.5 min, 20% at 7.5 min, 45% at 14 min, 99% at 20 to 23 min, and 0% from 23.1 to 27.1 min. The autosampler temperature was set to 4 °C and 5 µL of sample was injected. Samples were measured in the negative ESI mode with capillary voltage at −3.5kV. Further source settings were as follows: gas temperature, 250 °C; gas flow, 13 L/min; nebulizer, 35 psi; sheath gas temperature, 325 ºC; sheath gas flow, 12 L/min; nozzle voltage, 500 V; and delta EMV, -200. Acquisition was performed in dynamic multiple reaction monitoring (dMRM) mode with fragmentation pattern and retention time setting as Table SI .

    Search related documents:
    Co phrase search for related documents
    • acetic acid and ESI mode: 1, 2, 3
    • acetic acid and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acetic acid and gas flow: 1
    • acetic acid and gas temperature: 1
    • capillary voltage and ESI mode: 1
    • capillary voltage and flow rate: 1, 2
    • capillary voltage and gas flow: 1, 2
    • capillary voltage and gas temperature: 1, 2
    • capillary voltage and LC separation: 1
    • ESI mode and flow rate: 1, 2, 3, 4, 5
    • ESI mode and gas flow: 1, 2
    • ESI mode and gas temperature: 1, 2
    • flow rate and fragmentation pattern: 1
    • flow rate and gas flow: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • flow rate and gas temperature: 1, 2, 3, 4, 5, 6