Author: Mattson, Alexander R; Zhingre Sanchez, Jorge D; Iaizzo, Paul A
Title: The fixation tines of the Micraâ„¢ leadless pacemaker are atraumatic to the tricuspid valve. Cord-id: f2vo3duv Document date: 2018_1_1
ID: f2vo3duv
Snippet: BACKGROUND Today, there is no manufacturer-supplied retrieval tool for the Micraâ„¢ pacemaker (Medtronic, Minneapolis, MN, USA); therefore, off-the-shelf catheters have been employed for retrievals. The proximal retrieval feature of the Micraâ„¢ can be snared and the device is then retracted from the myocardium, pulling the device through the tricuspid valve. This study characterizes the potential risks of Micraâ„¢ nitinol tine engagement with the tricuspid sub-valvular apparatus. METHODS Fresh
Document: BACKGROUND Today, there is no manufacturer-supplied retrieval tool for the Micraâ„¢ pacemaker (Medtronic, Minneapolis, MN, USA); therefore, off-the-shelf catheters have been employed for retrievals. The proximal retrieval feature of the Micraâ„¢ can be snared and the device is then retracted from the myocardium, pulling the device through the tricuspid valve. This study characterizes the potential risks of Micraâ„¢ nitinol tine engagement with the tricuspid sub-valvular apparatus. METHODS Fresh human hearts nonviable for transplant (n = 10) were obtained from our regional organ procurement agency (LifeSource, Minneapolis, MN, USA). Micraâ„¢ fixation tines were affixed to a linear force transducer. Tines were then engaged in tricuspid chordae tendineae to conduct a constant velocity tensile test. Each test was run until tines disengaged from the chordae tendineae or until they released from the valve apparatus. Subsequently, biomechanical failure properties of the valve apparatus and isolated chordae tendineae were determined using a series of uniaxial tensile tests. RESULTS There were no chordal ruptures observed during our Micraâ„¢ tine extraction testing. Chordal failure required 15.0 times the force of extracting a single engaged tine, and 9.0 times the force of extracting two engaged tines. The uniaxial stresses required for isolated chordal failure averaged 17.4 N/mm2 ; failure strains exceeded 150% resting chordal length. CONCLUSIONS The forces required to rupture tricuspid chordae tendineae significantly exceeded the forces potentially imposed on the chordae during Micraâ„¢ device retrievals. We conclude that the fixation tines of the Micraâ„¢ device are unlikely to damage the tricuspid apparatus during either implant or retrieval.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date