Author: Egerer, Renate; Edel, Birgit; Löffler, Bettina; Henke, Andreas; Rödel, Jürgen
Title: Performance of the RT-LAMP-based eazyplex® SARS-CoV-2 as a novel rapid diagnostic test Cord-id: fotfimaz Document date: 2021_4_1
ID: fotfimaz
Snippet: BACKGROUND: Diagnostic assays for severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) that are easy to perform and produce fast results are essential for timely decision making regarding the isolation of contagious individuals. OBJECTIVE: We evaluated the CE-approved eazyplex® SARS-CoV-2, a ready-to-use real time RT-LAMP assay for identification of the SARS-CoV-2 N and ORF8 genes from swabs in less than 30 min without RNA extraction. STUDY DESIGN: Oropharyngeal and nasal swabs from 100
Document: BACKGROUND: Diagnostic assays for severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) that are easy to perform and produce fast results are essential for timely decision making regarding the isolation of contagious individuals. OBJECTIVE: We evaluated the CE-approved eazyplex® SARS-CoV-2, a ready-to-use real time RT-LAMP assay for identification of the SARS-CoV-2 N and ORF8 genes from swabs in less than 30 min without RNA extraction. STUDY DESIGN: Oropharyngeal and nasal swabs from 100 positive and 50 negative patients were inoculated into 0.9 % saline and tested by NeuMoDx™ RT-PCR. An aliquot was diluted fivefold in Copan sputum liquefying (SL) solution and directly analyzed by eazyplex® SARS-CoV-2. In addition, 130 patient swabs were prospectively tested with both methods in parallel. Analytical sensitivity of the assay was determined using virus stock dilutions. RESULTS: Positive percent agreement (PPA) between the eazyplex® SARS-CoV-2 and RT-PCR was 74 % for samples with Ct values < 35. When using a Ct cut-off ≤ 28 the PPA increased to 97.4 %. In the prospective part of the study overall PPA of the eazyplex® kit was 66.7 % but increased to 100 % when only Ct values ≤ 28 were considered. There were no false positive results. The median time to positivity was 12.5 min for the N gene and 16.75 min for ORF8. Analytical sensitivity was 3.75 TCID(50)/mL. 10(5) virus copies/mL were reproducibly detected. CONCLUSION: The eazyplex® SARS-CoV-2 is a rapid assay that accurately identifies samples with high viral loads. It may be useful for near-patient testing outside of a molecular diagnostic laboratory.
Search related documents:
Co phrase search for related documents- achilles heel and acute respiratory syndrome: 1, 2, 3
- acute respiratory syndrome and additional equipment: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- acute respiratory syndrome and additional problem: 1
- acute respiratory syndrome and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory syndrome and lysis control: 1
Co phrase search for related documents, hyperlinks ordered by date