Author: Chu, Jiyon; Shin, Juyoun; Kang, Shinseok; Shin, Sun; Chung, Yeun-Jun
Title: Rapid and sensitive detection of Salmonella species targeting the hilA gene using a loop-mediated isothermal amplification assay Cord-id: dgq8yinm Document date: 2021_9_30
ID: dgq8yinm
Snippet: Salmonella species are among the major pathogens that cause foodborne illness outbreaks. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of Salmonella species. We designed LAMP primers targeting the hilA gene as a universal marker of Salmonella species. A total of seven Salmonella species strains and 11 non-Salmonella pathogen strains from eight different genera were used in this study. All Salmonella strains showed p
Document: Salmonella species are among the major pathogens that cause foodborne illness outbreaks. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of Salmonella species. We designed LAMP primers targeting the hilA gene as a universal marker of Salmonella species. A total of seven Salmonella species strains and 11 non-Salmonella pathogen strains from eight different genera were used in this study. All Salmonella strains showed positive amplification signals with the Salmonella LAMP assay; however, there was no non-specific amplification signal for the non-Salmonella strains. The detection limit was 100 femtograms (20 copies per reaction), which was ~1,000 times more sensitive than the detection limits of the conventional polymerase chain reaction (PCR) assay (100 pg). The reaction time for a positive amplification signal was less than 20 minutes, which was less than one-third the time taken while using conventional PCR. In conclusion, our Salmonella LAMP assay accurately detected Salmonella species with a higher degree of sensitivity and greater rapidity than the conventional PCR assay, and it may be suitable for point-of-care testing in the field.
Search related documents:
Co phrase search for related documents- acid amplification and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- acid amplification and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
- acid amplification and lysis buffer: 1
- acid amplification method and lod detection: 1, 2
- acid amplification method and lod detection limit: 1
- acid amplification method and low sensitivity: 1
- acid amplification method and lysis buffer: 1
- lod detection and low sensitivity: 1, 2, 3, 4, 5, 6
- lod detection and lysis buffer: 1, 2, 3
- lod detection limit and low sensitivity: 1, 2, 3, 4, 5, 6
- lod detection limit and lysis buffer: 1, 2, 3
- low sensitivity and lysis buffer: 1
Co phrase search for related documents, hyperlinks ordered by date