Selected article for: "abbott panbio and low sensitivity"

Author: Torres, I.; Poujois, S.; Albert, E.; Colomina, J.; Navarro, D.
Title: Real-life evaluation of a rapid antigen test (Panbio COVID-19 Ag Rapid Test Device) for SARS-CoV-2 detection in asymptomatic close contacts of COVID-19 patients
  • Cord-id: o852t79m
  • Document date: 2020_12_2
  • ID: o852t79m
    Snippet: Objectives: There is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for the purpose. Methods: A total of 634 individuals (355 female; median age, 37 years; range, 9-87) were enrolled. Household (n=338) contacts were tested at a median of 2 days (range, 1-7) after diagnosis of the index case and non-
    Document: Objectives: There is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for the purpose. Methods: A total of 634 individuals (355 female; median age, 37 years; range, 9-87) were enrolled. Household (n=338) contacts were tested at a median of 2 days (range, 1-7) after diagnosis of the index case and non-household contacts (n=296) at a median of 6 days (range, 1-7) after exposure. RAD testing was carried out at the point of care. The RT-PCR test used was the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, Massachusetts, USA). Results: In total, 79 individuals (12.4%) tested positive by RT-PCR, of whom 38 (48.1%) yielded positive RAD results. The overall sensitivity and specificity of the RAD test was 48.1% (95% CI: 37.4-58.9) and 100% (95% CI: 99.3-100), respectively. Sensitivity was higher in household (50.8%; 95% CI: 38.9-62.5) than in non-household (35.7%; 95% CI:16.3-61.2%) contacts. Individuals testing positive by RAD test were more likely (P<0.001) to become symptomatic than their negative counterparts. Conclusion: The Panbio test displays low sensitivity in asymptomatic close contacts of COVID-19 patients, particularly in non-household contacts. Nonetheless, establishing the optimal timing for upper respiratory tract collection in this group seems imperative to pinpoint test sensitivity.

    Search related documents:
    Co phrase search for related documents
    • Try single phrases listed below for: 1
    Co phrase search for related documents, hyperlinks ordered by date