Selected article for: "electron microscope and transmission electron microscope"

Author: Yoo, Jhongryul; Jeong, Hongin; Park, Seo Kyung; Park, Sungho; Lee, Je Seung
Title: Interdigitated Electrode Biosensor Based on Plasma-Deposited TiO(2) Nanoparticles for Detecting DNA
  • Cord-id: biqmbxrm
  • Document date: 2021_6_29
  • ID: biqmbxrm
    Snippet: Bioelectrodes mediated by metal oxide nanoparticles have facilitated the development of new sensors in medical diagnosis. High-purity TiO(2) nanoparticles (NPs) were synthesized through thermal plasma and deposited directly on an interdigitated electrode. The surface of the TiO(2)-deposited electrode was activated with (3-aminopropyl) triethoxysilane (APTES) followed by fixing the single-stranded probe deoxyribonucleic acid (DNA) to fabricate the DNA biosensor. The structural properties of the d
    Document: Bioelectrodes mediated by metal oxide nanoparticles have facilitated the development of new sensors in medical diagnosis. High-purity TiO(2) nanoparticles (NPs) were synthesized through thermal plasma and deposited directly on an interdigitated electrode. The surface of the TiO(2)-deposited electrode was activated with (3-aminopropyl) triethoxysilane (APTES) followed by fixing the single-stranded probe deoxyribonucleic acid (DNA) to fabricate the DNA biosensor. The structural properties of the deposited TiO(2) nanoparticles were analyzed using a transmission electron microscope (TEM), X-ray diffraction (XRD), and a dynamic light scattering (DLS) system. The chemical composition and structural properties of the TiO(2) nanoparticle layer and the fixed layer were analyzed by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). E. coli O157:H7, a well-known pernicious pathogenic bacterial species, was detected as a target DNA of the prepared DNA biosensor, and the characteristics of DNA detection were determined by the current change using a picoammeter. The degree of binding between the probe DNA and the target DNA was converted into an electrical signal using the picoammeter method to quantitatively analyze the concentration of the target DNA. With the specificity experiment, it was confirmed that the biosensor was able to discriminate between nucleotides with mismatched, non-complementary, or complementary sequences.

    Search related documents:
    Co phrase search for related documents
    • active area and lod detection limit: 1
    • active area and low current: 1
    • active layer and lod detection: 1
    • active layer and lod detection limit: 1
    • lod detection and low accuracy: 1, 2
    • lod detection limit and low accuracy: 1, 2